Conventional MIG/MAG Welding (GMAW non synergic)
• With wire-feed speeds less than 8 m/min select JOB 188.
• With wire-feed speeds over 8 m/min select JOB 187.
You can only change the JOB number when no welding current is flowing.
Operating
element
Action
Result
Display
1 x
Select JOB list.
(LED
is on)
Set JOB number.
Wait 3 s until the setting has been applied.
5.7.7.1
Setting the operating point (welding output)
The operating point (welding performance) is set using the wire-feed speed and the welding voltage.
Operating
element
Action
Result
n x
Switch the display between:
Welding current (display of actual and hold value only)
Material thickness
Wire speed
After welding, the values used last
from the main program are displayed.
The settings are made using the rotary dials for welding parameter setting and arc length correction.
Operating
element
Action
Result
Increase or reduce the welding performance via the wire speed
parameter.
JOB 188: from 1-8 m/min
JOB 187: from 8-21 m/min
Operating
element
Action
Result
Set the welding voltage.
Setting range:
-9.9 V-9.9 V
Summary of Contents for Phoenix Expert drive 4L M3.70
Page 92: ...Appendix A JOB List 92 099 004846 EW501 8 01 2014 11 Appendix A 11 1 JOB List...
Page 93: ...Appendix A JOB List 099 004846 EW501 8 01 2014 93...
Page 94: ...Appendix A JOB List 94 099 004846 EW501 8 01 2014...
Page 95: ...Appendix A JOB List 099 004846 EW501 8 01 2014 95...
Page 96: ...Appendix A JOB List 96 099 004846 EW501 8 01 2014...
Page 97: ...Appendix A JOB List 099 004846 EW501 8 01 2014 97...
Page 98: ...Appendix A JOB List 98 099 004846 EW501 8 01 2014...
Page 99: ...Appendix A JOB List 099 004846 EW501 8 01 2014 99...
Page 100: ...Appendix A JOB List 100 099 004846 EW501 8 01 2014...