Design and function
MIG/MAG welding
46
099-005323-EW501
21.05.2014
5.8.4.6
Burn-back
ENTER
3 s
EXIT
3 s
Figure 5-12
Display
Setting/selection
menu burn back
Set burn back
Parameter setting (setting range 0 to 499)
Back-burn set too high: large drops developing on the wire electrode result in poor
ignition properties or the wire electrode sticking to the welding nozzle.
Back-burn set too low: Wire electrode sticks in the molten pool