Design and function
MIG/MAG welding
099-005323-EW501
21.05.2014
45
5.8.4.4
Choke effect / dynamics
EXIT
ENTER
3 s
Figure 5-10
Display
Setting/selection
Dynamics setting
40: Arc harder and narrower
-40: Arc softer and wider
5.8.4.5
superPuls
In superPuls mode, the program toggles from main program (PA) to reduced main program (PB). This
function is used e.g. in thin sheet welding to accurately reduce the heat input or weld vertical-up welds
without weaving. superPuls in combination with EWM welding processes offers many possibilities.
Welding performance can be represented as average value (ex works) or solely as program A value. If
the average value display is activated the signal lights of the main (PA) and reduced main program (PB)
are illuminated simultaneously. The display variants can be changed using special parameter P19, see
chapter "Special parameters (Advanced settings)".
EXIT
ENTER
3 s
Figure 5-11
Display
Setting/selection
Selects super pulses
Switches function on or off.
Switch on
Switching on machine function
Switch off
Switching off machine function