Design and function
TIG welding
82
099-005403-EW501
18.08.2016
5.4.7
TIG program sequence ("Program steps" mode)
Figure 5-65
Basic parameters
Item
Meaning/explanation
Setting range
1
Gas pre-flow time
0 s to 0.9 s
2
P
START
Ignition current
0% to 200%
3
Duration (start program)
0 s to 20 s
4
Slope duration from P
START
to P
A
0 s to 20 s
5
P
A
(main program)
Welding current, absolute
5 A to 550 A
6
Duration (P
A
)
0.01 s to 20.0 s
7
P
B
(reduced main program)
Welding current
1% to 100%
8
Duration (reduced main program)
0.01 s to 20.0 s
9
Slope duration from P
A
to P
END
0 s to 20 s
10
P
END
(end program)
Welding current
1% to 100%
11
Duration (end program)
0 s to 20 s
12
Gas post-flow time
0 s to 20 s
13
superPuls
on/off
P
START
, P
B
, and P
END
are relative programs whose welding current settings are a percentage based on the
general welding current setting.