Design and function
Special parameters (advanced settings)
100
099-005403-EW501
18.08.2016
Creating user-defined JOB lists
A consecutive memory range where accessories such as the POWERCONTROL 2 torch can be
used to switch between JOBs will be created.
• Set special parameter P12 to "2".
• Set "Program or Up/Down function" changeover switch to "Up/Down" position.
• Select an existing JOB which is closest to the required result.
• Copy JOB to one or more target JOB numbers.
If any JOB parameters need to be changed, select the target JOBs in sequence and change the
parameters individually.
• Set special parameter P13 to the lower limit and
• Set special parameter P14 to the upper limit of the target JOBs.
• Set "Program or Up/Down function" changeover switch to "Program" position.
JOBs can be changed over in the specified range using the accessory component.
Copying JOBs, "Copy to" function
The possible target range is between 129 - 169.
• First configure special parameter P12 to P12 = 2 or P12 = 1!
3s
5s
By repeating the last two steps, the same source JOB can be copied to multiple target JOBs.
If the control does not register any user activity for longer than 5 seconds, the parameter display is shown
once more and the copy process is complete.