Design and function
Access control
88
099-005402-EW501
24.11.2016
5.6
Access control
To protect against unauthorised or unintentional adjustment of the welding parameters on the machine,
the control input can be locked with the aid of a key switch.
In key switch position 1 all functions and parameters can be set without restriction.
In key switch position 0 the following functions and parameters cannot be changed:
• No adjustment of the operating point (welding performance) in programs 1–15.
• No change of welding or operating mode in programs 1–15.
• The welding parameters can be displayed but not changed in the control's function sequence.
• No welding task switching (JOB block operation P16 possible).
• No change of special parameters (except P10). Restart required.
5.7
Remote control
The remote controls are operated via the 19-pole remote control connection socket (analogue) or
the 7-pole remote control connection socket (digital), depending on the model.
Read and observe the documentation to all system and accessory components!
5.8
Power-saving mode (Standby)
You can activate the power-saving mode by either pressing the push-button
> see 4.4 chapter
for a
prolonged time or by setting a parameter in the machine configuration menu (time-controlled power-
saving mode
)
> see 5.12 chapter
.
When power-saving mode is activated, the machine displays show the horizontal digit in the
centre of the display only.
Pressing any operating element (e.g. tapping the torch trigger) deactivates power-saving mode and the
machine is ready for welding again.