Design and function
Welding data display
099-005402-EW501
24.11.2016
33
5.2
Welding data display
To the left and right of the control displays are the "Parameter selection" buttons (
). They are used to
select welding parameters to be displayed.
Each press of the button advances the display to the next parameter (LEDs next to the button indicate the
selection). After the last parameter is reached, the system starts again from the beginning.
Figure 5-11
The display shows:
• Nominal values (before welding)
• Actual values (during welding)
• Hold values (after welding)
MIG/MAG
Parameter
Nominal values
Actual values
Hold values
Welding current
Material thickness
Wire feed speed
Welding voltage
Welding performance
TIG
Parameter
Nominal values
Actual values
Hold values
Welding current
Welding voltage
Welding performance
MMA
Parameter
Nominal values
Actual values
Hold values
Welding current
Welding voltage
Welding performance
When settings are changed (e.g. wire feed speed) the display immediately switches to nominal
value setting.