Known problems and their solutions 

 

No control Pelco Speed Dome - the green LED blinks during control, the red LED does not blink 

1.  Set the green LED to display only valid packets. 
2.  If the green LED is not blinking, check the connection and transmission parameters. 
3.  If the green LED is blinking, check if the camera address you want to control is set in the converter. 

 

No control Pelco Speed Dome – the green LED blinks on the control, the red LED blinks from time to time. 

1.  Check the correct connection between the converter and the keyboard. 
2.  Check if the RS-485 terminating resistors are included in the keyboard and converter, if the distance 

between the converter and the keyboard are over 100m 

3.  Check the power supply stability of the converter 
 

No control Pelco Speed Dome – green and red LED blinks. 

1.  Check the correct connection of the cables between the converter and the camera. 
2.  Check if the Pelco output protocol is suitable for the controlled cameras, check transmission baud rate. 
3.  Check if the termination is configured following the rules of RS-485.  
4.  Check the baud rate and camera address settings. 

 

Time to time there is no camera control or the camera rotates continuously and cannot be stopped. 

1.  Set the red LED to display erroneous packets. 
2.  If the red LED blinks frequently, transmission is interrupted as a result of incorrect connections or data 

collision with another control device. 

3.  Check if the termination resistors are included in the converter and in the camera. 
4.  Possible interference from the ground loop effect - a data separator is required. 

 
No LED’s light up when attempting to control.

 

1.  Set the green LED to display all data. 
2.  If the green LED is blinking, verify the baud rate and protocol settings on PTZ keyboard and in the 

converter. 

3.  If the green LED is not blinking, check the connections between the keyboard and the converter. 

4. 

Check the converter power supply. Restart power - after connecting power supply red diode should blinks 
several times.

 

 
 

The device failed to start despite the above tips? Contact Ewimar Sp z o.o. Technical Support.

 

 
 
 

The converter is a specialized product and to connect and run this product, basic electronic knowledge, 
knowledge of communication interfaces and issues related to the installation of CCTV devices are 
necessary. The manufacturer is not liable for losses related to the use of the device, failure to operate or 
damage caused by the lack of proper knowledge of the user. This manual does not convey general 
knowledge, only information applicable to this product. 
 
In the absence of operation or malfunction of the device or any complaint, please contact the 
manufacturer immediately. 
 

 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for CONV Bosch To Pelco Standard

Page 1: ...SB and Ewimar Firmware Upgrader Configurator 9 Possibility to change the firmware to others when the converter will no longer be used in the existing system only at the cost of the software Supported...

Page 2: ...d is converted to range used in Pelco protocols Connection structure The converter has one input port for Bosch Biphase OSRD and two Pelco output ports each of which is freely configurable as Pelco D...

Page 3: ...AC DC 485 A 1 10 485 B GND 485 A 485 B GND 485 A 485 B Pelco Speed Dome Pelco Speed Dome C C GND A B GND A B GND POWER Connect a power source in the range 9 24V AC DC any polarity GND Power Ground com...

Page 4: ...ed in the converter 1 Protocol type for Port 1 Command P1 x Selection of communication protocol for the PTZ keyboard P1 0 Biphase D P1 1 OSRD 2 Protocol type for Port 2 Command P2 x Selection of commu...

Page 5: ...ve in Lite version active in Standard version after purchasing the license 12 Advanced joystick correction Command CPx y i CTx y Described in the extended manual downloaded with the Get user manual bu...

Page 6: ...ly and cannot be stopped 1 Set the red LED to display erroneous packets 2 If the red LED blinks frequently transmission is interrupted as a result of incorrect connections or data collision with anoth...

Page 7: ...ved for work within the EU and is compliant with essential requirements and other relevant provisions of EMC Directives 2014 30 EU and 2011 65 EU RoHS directive PN EN 61000 6 3 2008 A1 2012 Electromag...

Reviews: