background image

CONV Bosch To Pelco - firmware 0.01.xx 

Ewimar Sp. z o.o. 
www.ewimar.pl 

Made in Poland 

DECLARATION OF CONFORMITY

 

 

 

 

PRODUCT:

 

 

 

 

 

PTZ Protocol Converter

 

 

MODEL:  

 

CONV Bosch To Pelco 

  
 
 

MANUFACTURER:

 

 

Ewimar  Sp. z o.o.  

ul. Konarskiego 84, 01-355 Warszawa 

 

We hereby declare that the above product is approved for work within the EU and is compliant with 

essential requirements and other relevant provisions of EMC Directives 2014/30 / EU and 2011/65 / EU - 

RoHS directive:

 

 

PN-EN 61000-6-3: 2008 / A1: 2012 - Electromagnetic compatibility (EMC) - Part 6-3: General standards -

Emission standard in residential, commercial and slightly industrialized environments 

 

  

 

 

Warsaw 2nd March 2020 r.

                                                                             Ewimar Sp. z o.o. 

 

 
 
 
 
 
 
 
 
 

Manufacturer: 
Ewimar Sp. z o.o., ul.Konarskiego 84, 01-355 Warsaw. Phone +48 22 691-90-65, [email protected] 

Summary of Contents for CONV Bosch To Pelco Standard

Page 1: ...SB and Ewimar Firmware Upgrader Configurator 9 Possibility to change the firmware to others when the converter will no longer be used in the existing system only at the cost of the software Supported...

Page 2: ...d is converted to range used in Pelco protocols Connection structure The converter has one input port for Bosch Biphase OSRD and two Pelco output ports each of which is freely configurable as Pelco D...

Page 3: ...AC DC 485 A 1 10 485 B GND 485 A 485 B GND 485 A 485 B Pelco Speed Dome Pelco Speed Dome C C GND A B GND A B GND POWER Connect a power source in the range 9 24V AC DC any polarity GND Power Ground com...

Page 4: ...ed in the converter 1 Protocol type for Port 1 Command P1 x Selection of communication protocol for the PTZ keyboard P1 0 Biphase D P1 1 OSRD 2 Protocol type for Port 2 Command P2 x Selection of commu...

Page 5: ...ve in Lite version active in Standard version after purchasing the license 12 Advanced joystick correction Command CPx y i CTx y Described in the extended manual downloaded with the Get user manual bu...

Page 6: ...ly and cannot be stopped 1 Set the red LED to display erroneous packets 2 If the red LED blinks frequently transmission is interrupted as a result of incorrect connections or data collision with anoth...