19
7.0 O p eration
7.4 Installation instruction
CASM parallel kit
7.4.1 Use as intended
The adapter kit allows a parallel motor mounting (⮑ 7.4.2
Recommended motors, page 19) to a CASM linear unit.
7.4.2 Recommended motors
In principle, all motors that are equipped with an smooth
shaft may be fitted. It is important that the rated torque and
speed of the motors does not exceed the permitted values
of the linear unit. Detailed information may be found in the
technical notes relating to the electric cylinders. Ewellix rec-
ommends the following SIEMENS 1FK7 servo motors:
(⮑ table 1).
Table 1
Recommended CASM linear unit /Siemens servo motor combinations
Linear unit
CASM–32
CASM–40
CASM–63
Screw
TR
9×1,5
KGT
10×3
KGT
10×10
TR
12,5×2.5
KGT
12×5
KGT
12,7×12,7
TR
20×4
KGT
20×10
KGT
20×20
Motor
1FK7015
1FK7022 / 1FK7034
1FK7034
7.4.3 Screws and tightening torques M
A
Table 2
Screw size/tightening torques
SB (Intermediate plate)
S1 (Cover)
S2 (Cover)
S3 (Cover)
Screw
Torque M
A
Screw
Torque M
A
Screw
Torque M
A
CASM–32
–1FK7015
M6×20
5,9 Nm
±0,8 Nm
M6×20
4,0 Nm
±0,5 Nm
M4×30
4,0 Nm
±0,5 Nm
M4×16
3,0 Nm
±0,3 Nm
CASM–40
–1FK7022
M6×20
5,9 Nm
±0,8 Nm
M6×20
4,0 Nm
±0,5 Nm
M4×35
4,0 Nm
±0,5 Nm
M5×20
5,9 Nm
±0,8 Nm
CASM–63
–1FK7034
M8×24
10,1 Nm
±0,8 Nm
M8×20
5,9 Nm
±0,8 Nm
M4×45
4,0 Nm
±0,5 Nm
M6×20
10,1 Nm
±0,8 Nm
Summary of Contents for CASM-32