10
CA S M
4.3 Overview
4.3.1 CASM accessories overview
Fig. 3
CASM accessories
1. Linear unit
2. Proximity sensor
3. a and b Foot axial mounting kit
4a. Trunnion mounting kit (on casing tube)
4b. Trunnion support
5a. Trunnion flange kit with pair of support (front)
5b. Trunnion support
6. Flange mounting kit
7. Rod eye
8. Rod clevis
4.3.2 Parallel adater kit
Fig. 4
Parallel adater kit
1a. Intermediate plate
1b. Gear box cover
2. Swivel flange with rod eye
3. Swivel flange
Specific details about accessories and adapter kits
(⮑11 Appendix, page 28).
8
1
7
2
3a
3b
5b
4b
4a
6
5a
4.4 Sensor mounting
• The sensor can be inserted into the grooves by sliding it in
from the front. (⮑ Fig. 6).
• Install the sensors: the sensors can be slided into the
grooves from the front of the actuator. The cable ends
should lead to the direction of the motor. Push the sensors
to their approximate positions in the grooves of the cylin-
der body. Tighten the fixing screws on the proximity switch
slightly and lead the cable along the profile groove.
Insert the cables into the grooves of the plastic covers and push
the cover into the groove together with the cable.
Fig. 5
1b
2
3
1a
Summary of Contents for CASM-32