3.0 Te chnic al data
9
NOTE
The technical data (dimensions, weight, output, connection values
etc.) can be found in the enclosed drawings and data sheets (⮑ 11
Appendix, page 37).
3.1 Operating conditions
Environment
Information
Value
Unit
Temperature range
–40 to +85 °C
Relative atmospheric humidity,
maximum (no build up of condensation)
up to 96
%
NOTE
• Below 0 °C: load capacity and speed will decrease
• Above 40 °C: temperature of the motor will increase and the duty
cycle and running time could be decreased
12 V DC version – Duration (intermittent)
Information
Value
Unit
Maximum operating time without a break 85
sec.
Maximun break until next operation,
9 time of operating time
765
sec.
Max duty cycle at rated load: 10% (85 s on / 765 s off)
E design : 24 & 48 V DC version
S design : 24 & 48 V DC version – Duration (intermittent)
Information
Value
Unit
Maximum operating time without a break 85
sec.
Maximum break until next operation,
4 time of operating time
340
sec.
Max duty cycle at rated load: 20% (85 s on / 340 s off)