Safety Instruction - CAUTION

Any operation that is inconsistent with the contents of the instructions may cause serious 

personal injury or damage to the product itself. 

Do not stare at the UV lamp directly at any time to avoid injury. If you have a sensitive skin 
complaint then do not use without consulting your doctor.   

1.

UV rays can damage the skin and eyes of people and animals. Do not aim the UV light

directly at the human body, plants or animals.

2.

Do not modify or block the rollers (safety switches) on the bottom of the product so the

UV lamp loses its safety protection.

3.

Please do not touch the handheld vacuum cleaner plug with wet hands to avoid the risk

of electric shock.

4.

Do not leave the unit plugged in when not working. When not in use or before any

maintenance, please unplug from the power supply.

5.

To reduce the risk of electric shock, do not use it outdoors or on wet surfaces.

6.

Do not use when the plug or power cable is damaged. When the product appears to have

been dropped, damaged or fallen into water, or doesn’t work, please contact our service

department for repair.

7.

This product is for general home use, please do not use it for commercial or other

purposes.

8.

Do not suck sharp hard objects such as glass, screws, construction waste etc. to avoid

damage to the machine.

9.

Do not pull by the power cable to remove from the socket. Do not put this unit on a hot

surface.

10.

Before unplugging the power plug, first use the power switch on the unit to turn the unit

off. When installing the vacuum accessories ensure the power switch is turned off first.

11.

Please stop using when any duct is clogged, otherwise this may damage the motor. Keep

away from dust, lint, hair and anything that can clog the air flow when stored.

12.

Keep hair, clothing, mobile phones and any part of the body away from the vacuum

cleaner when operating.

13.

Do not use on burning or smoking objects such as cigarette, matches or hot ash.

14.

Do not use when dust cup or filters are not properly installed. Otherwise this will damage

the motor.

15.

Do not cover air vent

16.

Do not touch the UV lamp after use, as this may be hot and burn your skin.

17.

If the power cable is damaged, the power cable must be replaced by a qualified person or

a designated service centre. Do not disassemble by yourself.

NOTE: Some special groups are not suitable for this product, such as children,
people with reduced physical, sensory or mental capabilities, or people who lack
the experience and knowledge. Unless they are supervised to ensure the safety of
use of the product. Make sure children do not treat the product as a toy.

Summary of Contents for UV400

Page 1: ...UV400 Bed Cleaner Hand Vacuum Care and Use Instructions Ewbank LLC 6801 D Northpark Boulevard Charlotte NC 28216 Tel 704 827 9385 enquiries ewbankus com www ewbankus com ...

Page 2: ... suck sharp hard objects such as glass screws construction waste etc to avoid damage to the machine 9 Do not pull by the power cable to remove from the socket Do not put this unit on a hot surface 10 Before unplugging the power plug first use the power switch on the unit to turn the unit off When installing the vacuum accessories ensure the power switch is turned off first 11 Please stop using whe...

Page 3: ... Whilst in bed we shed our dead skin which makes its way into the fibres of our bedding and mattress The Dust Mites feed on this dead skin and in turn it is their faeces that many people are allergic to The warmth and moisture from our bodies help cultivate fungi and bacteria which also live on the dead skin leaving our beds a breeding ground for allergies Dust Mites and their faeces are proven to...

Page 4: ...age allergy filtration will safely and efficiently assist in the eradication and removal of Dust mites and their faeces from our beds The sleep enhancer will provide a lavender aroma that is known to help aid sleep so that you can enjoy a good night s rest Product Features 1 UV Head 10 UV head lock 2 LED indicator 11 14 Vibrator switch on off 3 Dust chamber 12 Outlet HEPA filter 4 Filter 13 UV lam...

Page 5: ...EE in optimum performance Replace the UV C lamp every 2 3 years Replace the main HEPA filter every 12 18 months Replace the Exit filter every 12 18 months Replace the sleep enhancer cartridge every month Replacement Parts for your UVEE Replacement parts for your UVEE may be purchased from your local dealer or alternatively go to www ewbankus com for price and availability information 1 6 Pack slee...

Page 6: ...ine lights up indicating that the UV lamp has started to work and then move the machine forwards and backwards slowly to clean the items Do not raise the unit from the surface as this will turn the UV off for your protection The recommended cleaning time is no less than 20 seconds per metre backwards and forwards three times 4 If you need to use the vibrator function you can press the vibrator swi...

Page 7: ...ecial adaptor at the front of handheld vacuum cleaner inlet then install one of the various accessories supplied Extension tubes are supplied for use for area difficult to reach Now you can use to clean items like floors furniture curtains and other objects 6 Sleep enhancer disc assembly use To enhance your sleeping experience Ewbank lavender sleep enhancer cards are available for your UVEE Lavend...

Page 8: ...r B to cover and clean the whole mattress Keep the UVEE flat on the surface and ensure you move the UVEE smoothly and steadily as you would with a household vacuum figure A or B Cleaning and Maintenance of the UVEE Regularly clean the HEPA filter because the collection of dust mites into the filter may not always kill them and they may continue to breed In order to avoid secondary pollution please...

Page 9: ...r stains on the tube will have a direct impact on UV lamp s penetration ability The quartz lamp should be regularly cleaned so the performance will not be affected o First make sure the machine is turned off then turn the machine over remove the screw with a cross screwdriver then open the UV lamp cover and remove the UV lamp assembly with lamp holder o After the UV lamp assembly is removed pinch ...

Page 10: ...avoid the vacuum cleaner failing Do not use in or near water The unit is not suitable for cleaning with oil or gasoline Use only a soft cloth or neutral detergent to wipe clean the outside of the unit Coil the power cord neatly for storage Keep it in a dry place Do not place heavy objects on top of the machine 7 Cleaning and replacing the Exit Filter Turn off the machine and unplug the power cable...

Page 11: ...move the dust chamber and carefully remove the blockage from the air duct Do not use sharp tools as these may damage your unit Reduced suction Dust cup is full or HEPA filter is too dirty Empty and gently wash the filter in water The filter must be completely dry before use Dust leaks out during using Dust chamber is damaged Replace the dust chamber Call sales department to purchase new part Filte...

Page 12: ...bank LLC to ensure that our products leave the factory in good working order Ewbank LLC cannot under any circumstances accept liability for problems or damage caused by their subsequent use It is the responsibility of the user to ensure the surfaces to be treated or cleaned are suitable for vacuuming This guarantee does not affect your statutory rights This guarantee excludes the use for rental or...