Operation interface
Outlines of this chapter
Introduce the display, operation, buttons and LED light of the inverter.
6.1 Operation and Display Panel
Buttons and Indicator lights
GFCI Warning
Inverter States Light
Warning Light
6.2 Standard Interface
LCD standard interface is used to display inverter states information and parameter setting etc.
LCD displays the updates of inverter energy
、
power
、
input information warning information etc.
A1 - Indicates Modbus communication address.
。
A2 - RS485 communicating
Ba
c
k
Up
Down
OK
Key-button:
·
Back
: to back up or enter into main interface at standard interface states
·
Up
: to move up or increase value
·
Down
: to move down or decrease value
·
Enter
: to confirm selection
Indicator Lights:
·
States Light (GREEN)
Flashing: Waiting or checking state
ON: Normal operation
OFF: Fault or permanent state
·
Warning Light (RED)
Flashing: Fans fault
ON: The inverter is faulty OFF:
Normal operation
·
GFCI Warning Light (RED)
ON: GFCI fault
OFF: GFCI normal
A4 - WIFI communicating
A4- Wi-Fi Communicating
A3 - Light ON for RS485 communicating
A5 - Light flashes to warn over frequency and power derating. Light ON to warn remote switch off
A6 - Indicates
today’s energy
A7 - Indicates the total energy
A10 - MPPT SCAN function is activated (not available)
A9 - Indicates real time output power
A8 - Light ON warning for inverter high temperature
A11 - Light ON when input voltage over 250V
A12 - Indicates real time input voltage and current channel
A13 - Indicates the input voltage and current of phase 1&2 and displays in turns in every three
seconds
A14 - Light ON when the state is n
A16 - Indicates R/T/S phase current or frequency and displays in turns in every three seconds
A15 - Indicates R/T/S phase voltage and displays in turns in every three seconds