TROUBLESHOOTING
5.1 GENERAL TROUBLESHOOTING
TROUBLESHOOTING FOR QUALIFIED PERSONNEL ONLY
Follow commissioning guide to determine the nature of the fault.
•
PEN Loss .
Contact DNO or the utility company responsible for the supply
•
Single Phase monitoring
•
Is the EPC and socket/tethered cable correctly earthed? The 0V terminal on the EPC 2.0 should be
connected to Protective Earth in order for the system to operate correctly.
•
Ensure all connections in the EVSE are tightened to the correct Torque setting. For M3 terminals on
the EPC: 0.6
-
1.2Nm
-
(factory setting of 1nm). Consult relevant manufacturer documentation for oth-
er parts used
•
Check for correct operation of RCBO & Contactor
•
Check for a short between the CP and 0V terminal on EPC
•
Interlock does not action : Check LK FB , LK+ and LK
-
connections
LED
DESCRIPTION OF OPERATING STATE
COLOUR
STATUS
White
Flashing
lock is obstructed.
Purple
Steady
PEN Loss detected . The EPC 2.0 has disconnected the EVSE .
Contact DNO or the utility company responsible for the sup-
ply .
Red
Slow Pulsing
State E
•
Communication or Power fault to EV
•
EVSE Fault—Maintenance or repair required QUALI-
FIED PERSONNEL
Red
Fast Pulsing
•
RCM Fault: 6mA DC current detected
•
Diode Check Fail