Issue 1.2 May 2020
EVSE Protocol Controller 2.0 (EPC 2.0) | Viridian EV
5
DEVICE VERSIONS
•
The Viridian EV EPC 2.0 has part numbers in this format:
EPC20(1)(2)(3). i.e. EPC20 P10
-
R
• (1)
indicates the model B = Basic P = Plus
• (2)
indicates the revision number
• (3)
Presence of an R indicates supplied with RCM
SUPPLIED PARTS
EPC 2.0 module, Current Transformer (CT), RCM (when selected; optional part)
AREAS OF
APPLICATION & USE
•
Controlling the charging procedure of electric vehicles in accordance with IEC61851
mode 3
•
For communication with the electric vehicle according to IEC62196
-
2 or SAE J1172
MOUNTING
Mounting onto standard rail according to DIN EN 60715
CONNECTION ELEMENTS
•
Mains input
(207
—
257
V @ 50Hz AC)
•
2 Relay contacts (230V AC ) for switching the load and Aux contactor
•
Solenoid or motor interlock drive for socket (Configuration dependant)
•
Current Transformer (PEN Loss detection on single phase systems)
•
Vehicle interface / Signalling contacts
•
Operating current input (IC)
-
voltage or resistance
•
External LED support
INTEGRATED LED
Displays the operating state of EVSE
Operating Temp
-
25 to 50 C
Configurable options
•
Ability to restrict charging current ( IC ) up to system maximum.
•
Tethered or Socket outlets
•
16A or 32A maximum operating currents depending on fitted system contactor
•
Solenoid or motor locking systems
•
Interlock Feedback for status of motorised locks
•
RCM support enable / disable
•
Pen Loss enable / disable
•
Lock engaged polarity
3.2 EPC 2.0 FEATURES