14
TERMINAL DESCRIPTION
PE
Connects to ground connection of the electricity
supply or earth connection.
Y, G and R Protected connection for yellow (Y), green (G) and red
(R) LED. Connects to anode (+) pole of LED. The
cathode of LED should be connected to PE.
B
Solenoid or motor signal connection.
1
R
Solenoid or motor power connection.
1
W
Solenoid or motor power connection.
1
CP
Control Pin. Connects to the CP of IEC61851/J1772
EVSE socket/plug.
PP
Proximity Pin. Connects to the PP of IEC61851 EVSE
socket.
IC
Input Current. Connects to input current limit selecting
resistor, switch or dial. Input current limit resistor
values are listed further in the document.
1
For details on use with solenoid or motor lock please see section