4
Evo Flex Manual
2.2 Technical Data
Evo Flex
10
17
25
Cooling Capacity
kW
10
14.5
20
BTU/h
34121
49489
68260
Heating Capacity
kW
11.5
16.5
25
BTU/h
39240
56315
85325
Hot Water Capacity
kW
13.2
21.6
30
BTU/h
45040
73702
102364
Cooling Power Input
BTU/h
3.4
5.6
9.0
Heating Power Input
kW
3.4
5.1
9.0
Hot Water Power Input
BTU/h
3.6
6.2
8.2
Operation Electric Current (max)
kW
15.7
27
14.0
Cooling Capacity Range
kW
2.0 ~ 10
5.0 ~ 14.5
7.0 ~ 20.0
Heating Capacity Range
kW
2.5 ~ 11.5
5.0 ~ 16.5
8.0 ~ 25.0
Hot Water Capacity Range
A
4.2 ~ 13.2
7.4 ~ 21.6
11.0 ~ 30.0
Cooling Power Input Range
kW
1.0 ~ 3.4
1.6 ~ 5.6
2.5 ~ 9.0
Heating Power Input Range
kW
0.8 ~ 3.4
1.2 ~ 5.1
2.5 ~ 9.0
Hot Water Power Input Range
kW
1.0 ~ 3.6
1.5 ~ 6.2
2.1 ~ 8.2
Power Supply
230V~/50Hz
230V~/50Hz
380V/3N~/50Hz
Compressor Quantity
1
1
1
Compressor Model
Rotary
Rotary
Rotary
Fan Quantity
1
2
2
Fan Power Input
W
75
75 X 2
150 X 2
Fan Rotate Speed
RPM
850
850
900
Noise
dB(A)
54
58
62
Water Pump Input
kW
0.18
0.5
0.65
Water Head
m
12.5
21
22.5
Water Connection
inch
1
1 1/4
1 1/4
Water Flow Volume
m
3
/h
1.6
2.8
4.2
Water Pressure Drop (max)
kpa
24
105
71
Unit Net Dimensions (L/W/H)
mm
953*445*910
996*395*1320
1175*400*1592
Unit Shipping Dimensions (L/W/H)
mm
1040*490*920
1070*435*1340
1225*430*1600
Net Weight
kg
See Nameplate
See Nameplate
See Nameplate
Shipping Weight
kg
See Package Label See Package Label
See Package Label
Cooling Working Condition: (DB/WB)35°C/24°C, (outlet/inlet) 7°C/12°C
Heating Working Condition: (DB/WB) 7°C/6°C, (outlet/inlet) 35°C/30°C
Hot Water Working Condition: (DB/WB) 20°C/15°C, (outlet/inlet) 40°C/45°C
BS EN 14511-1-2013 Air Conditioner, whole liquid cooling machine, electric compressor.
Part 2: Test condition Part 3: Test Method
Part 4: Related requirements.