6
5. Countertop Installation (1 of 4)
Step. 2
Mark the finished position of the AGA 25G drip pan on the countertop using the dimensions shown. The circular
dimension of 1805mm (31” 11/16”) is the diameter of the drip pan to the outside flange material thickness (located to the
inside of the half-rolled bead edge). The drip pan cutout must be made precisely to these dimensions (or at a maximum
+1.5mm (1/16”)) so that the half-rolled top bead on the drip pan edge overhangs the cutout dimension by 6mm (.25”).
(
See following page for more details
).
11
3 4
"
299mm
31
1116
"
805mm
24"
610mm
12"
305mm
1
23 32
"
44mm
1
15 64
"
32mm
22
1 2
"
572mm
1
13 32
"
36mm
12"
305mm
Countertop
with substrate
underlayment
Opening in countertop front
From countertop front to center of drip pan cutout.
Cabinetry box:
1-1/2” below
countertop surface
TOP VIEW
NOTE:
If the dimensions for the
countertop overhang and
countertop depth cutout
are not followed, there will
be a conflict with the door
swing which may hinder
access to the spillover
waste containers.
Countertop
overhang to
cabinet front
Summary of Contents for AGA AGA-10-0096-LP-CE