SPECIFICATIONS AND TECHNICAL DATA

Model

Model

Height

Staple Length

Shank Dia.

Crown Width

Length

Loading Capacity

Width

Weight

Air Consumptionat 

6.9 bar (100PSI) Pressure

SN65Q

SN65S5

SN65Q

SN65S5

305mm (12.0")

305mm (12.0")

32~65mm (1-1/4"~2-1/2")

32~65mm (1-1/4"~2-1/2")

1.90 x 1.70mm (0.075" x 0.064")

1.60 x 1.40mm (0.062" x 0.055")

11.3mm (0.44")

10.8mm (7/16")

365mm (14.4")

365mm (14.4")

130

150

92mm (3.6")

92mm (3.6")

2.9 kgs (6.4 lbs)

2.9 kgs (6.4 lbs)

3.08 liter/second (6.5 cfm)

3.08 liter/second (6.5 cfm)

SPECIFICATIONS

FASTENER SPECIFICATIONS

TOOL AIR FITTING

This tool uses a 3/8"-19 P.T & 3/8"-18 N.P.T male plug. The inside diameter should be 7 mm (0.280") or larger. The fitting 
must be capable of discharging tool air pressure when disconnected from the air supply.

OPERATING PRESSURE

5 to 8bar (70 to 120PSI ). Select the operating pressure within this range for best fastener performance. Do not exceed this 
recommended operating pressure.

Type

15 GA. Senco Q Staples

16 GA. Bostitch BCS5/ 

Senco N/ BeA 155

9

Summary of Contents for SN65Q

Page 1: ...65S5 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE...

Page 2: ...d high volume fastening This tool delivers efficient and dependable service when used correctly with care As with any fine power tool the manufacturer s instructions must be followed for best performa...

Page 3: ...coverage is limited to 90 days due to high volume usage warranty on production tools cannot be guaranteed due to unpredictable circumstances Tools are subjected to abuse such as hammering or usage of...

Page 4: ...t ten tuotteen vastaavan seuraavla standardeja ja direktiivej 2006 42 EC ja EN ISO 11148 13 2018 CE Dichiarazione di conformit EVERWIN PNEUMATIC CORP dichiara assumendo la piena responsabilit che ques...

Page 5: ...nsure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the emplo...

Page 6: ...f the arm is not working correctly as accidental driving of a fastener may result Do not interfere with the proper operation of the contact arm mechanism Do not drive fasteners on top of other fastene...

Page 7: ...and appropriate gloves and protective clothing are recommended Appropriate hearing protection shall be worn Use the correct energy supply as directed in the manual To drive fasteners into hard surface...

Page 8: ...pain throbbing aching tingling numbness burning sensation or stiffness do not ignore these warning signs The operator should consult a qualified health professional regarding overall activities Disco...

Page 9: ...3 6 2 9 kgs 6 4 lbs 2 9 kgs 6 4 lbs 3 08 liter second 6 5 cfm 3 08 liter second 6 5 cfm SPECIFICATIONS FASTENER SPECIFICATIONS TOOL AIR FITTING This tool uses a 3 8 19 P T 3 8 18 N P T male plug The i...

Page 10: ...stem when using the tool will for example depend on the gripping force the contact pressure force the working direction the adjustment of mains supply and the workpiece support AIR CONSUMPTION 3 08 li...

Page 11: ...p available system on SN65Q ST SN65S5 ST The Sequential Trip requires the operator to hold the tool against the work before pulling the trigger This makes accurate fastener placement easier for instan...

Page 12: ...l may fracture or burst causing injury OPERATING PRESSURE Do not exceed recommended maximum operating pressure as tool wear will be greatly increased The air supply must be capable of maintaining the...

Page 13: ...ulting in poor tool performance and frequent tool maintenance If no air line lubricator is used add oil during use into the air fitting on the tool once or twice a day Only a few drops of oil at a tim...

Page 14: ...EVENT ACCIDENTAL INJURIES Never place a hand or any other part of the body in the discharge area of tool while the air supply is connected Never point the tool at anyone else Never engage in horseplay...

Page 15: ...te the tool in this manner hold the tool with the contact trip pointing towards but not touching the work surface Pull the trigger and then tap the contact trip against the work surface using a bounci...

Page 16: ...eaks air or does not function properly Notify your distributor or representative if your tool continues to experience functional problems 1 Contact Trip Operation 2 Sequential Trip Operation a The too...

Page 17: ...toward the nose to increase the drive of depth deep Tighten screw with 4mm hex key The DEPTH OF DRIVE ADJUSTMENT feature provides close control of the fastener drive depth from flush with the work su...

Page 18: ...ME Air volume is as important as air pressure The air volume supplied to the tool may be inadequate because of undersize fittings and hoses or from the effects of dirt and water in the system Restrict...

Page 19: ...from the air supply 2 Pull pusher into its pusher lock position as shown remove staples from the magazine 3 Open the jam clearing nose door by pulling down and then up on the latch 4 Remove the jammed...

Page 20: ...20...

Reviews: