background image

The vibration emission value reported in the operation manual is a tool-

related characteristic value and does not represent the influence to the 
hand-arm-system when using the tool. Any influence to the
hand-arm-system when using the tool will for example depend on the 
gripping force, the contact pressure force, the working direction, the 
adjustment of energy supply, the workpiece, the workpiece support.

Exposure to vibration can cause disabling damage to the nerves and 

blood supply of the hands and arms.

Wear warm clothing when working in cold conditions, keep your hands 

warm and dry.

If you experience numbness, tingling, pain, or whitening of the skin in 

your fingers or hands, seek medical advice from a qualified occupational 
health professional regarding overall activities.

Operate and maintain the tool as recommended in these instructions, to 

prevent an unnecessary increase in vibration levels.

Hold the tool with a light, but safe, grip because the risk from vibration is 

generally greater when the grip force is higher.

Compressed air can cause severe injury.

Always shut off air supply and disconnect tool from air supply when not in 

use.

Always disconnect the tool from the compressed air supply before 

changing accessories, making adjustments and /or repairs, when moving 
away from an operating area to a different area.

Keep fingers away from trigger when not operating the tool and when 

moving from one operating position to another.

Never direct compressed air at yourself or anyone else.

Whipping hoses can cause severe injury. Always check for damaged or 

loose hoses or fittings.

Never carry a pneumatic tool by its hose.

Never drag a pneumatic tool by its hose.

When using pneumatic tools, do not exceed the maximum operating 

pressure ps max.

Pneumatic tools should only be powered by compressed air at the lowest 

pressure required for the work process to reduce noise and vibration and 
minimize wear.

Using oxygen or combustible gases for operating pneumatic tools creates 

a fire and explosion hazard.

Be careful when using pneumatic tools as the tool could become cold, 

affecting grip and control.

When using a tool for long periods, the operator may experience 

discomfort in the hands, arms, shoulders, neck, or other parts of the body.

While using a tool, the operator should adopt a suitable but ergonomic 

posture. Maintain secure footing and avoid awkward or off-balanced 
postures.

If the operator experiences symptoms such as persistent or recurring 

discomfort, pain, throbbing, aching, tingling, numbness, burning sensation, 
or stiffness, do not ignore these warning signs. The operator should consult 
a qualified health professional regarding overall activities.

Disconnect the energy supply to the tool, such as air, gas, or battery, 

before changing /replacing accessories such as workpiece contact, or 
making any adjustments.

Use only the sizes and types of accessories that are provided by 

EVERWIN PNEUMATIC CORP.

Use only lubricants recommended by EVERWIN PNEUMATIC CORP.

slippery surfaces caused by use of the tool and also trip hazards caused 
by the airline hose.gripping force, the contact pressure force, the working 
direction, the adjustment of energy supply, the workpiece, the workpiece 
support.

Slips, trips, and falls are major causes of workplace injury. Be aware of 

slippery surfaces caused by use of the tool and also trip hazards caused by 
the airline hose.

Proceed with additional care in unfamiliar surroundings. Hidden hazards 

may exist, such as electricity or other utility lines.

This tool is not intended for use in potentially explosive atmospheres and 

is not insulated from coming into contact with electrical power.

Make sure there are no electrical cables, gas pipes, etc. that could cause 

a hazard if damaged by use of the tool.

If the tool is used in an area where there is static dust, it may disturb the 
dust and cause a hazard. Proceed with the following:

Direct the exhaust to minimize disturbance of dust in a dust filled 

environment.

Where dust or exhaust hazards are created, the priority shall be to control 

them at the point of emission.

The noise values reported in the operation manual are tool-related 

characteristic values and do not represent the noise generation at the point 
of use. Noise at the point of use will for example depend on the working 
environment, the workpiece, the workpiece support, and the number of 
driving operations.

Unprotected exposure to high noise levels can cause permanent,

disabling, hearing loss and other problems such as tinnitus (ringing, 
buzzing, whistling or humming in the ears).

Appropriate controls to reduce the risk may include actions such as 

damping materials to prevent workpieces from “ringing”.

Use appropriate hearing protection.

Operate and maintain the tool as recommended in these instructions, to 

prevent an unnecessary increase in noise levels.

If the tool has a silencer, always ensure it is in place and in good working 

order when the tool is being operated.

GENERAL SAFETY INSTRUCTION

Vibration  Hazards

Additional Safety Instructions for Pneumatic tools

Repetitive Motions Hazards

Accessory and Consumable Hazards

Workplace Hazards

Dust and Exhaust Hazards

Noise  Hazards

8

Summary of Contents for SN65Q

Page 1: ...65S5 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE...

Page 2: ...d high volume fastening This tool delivers efficient and dependable service when used correctly with care As with any fine power tool the manufacturer s instructions must be followed for best performa...

Page 3: ...coverage is limited to 90 days due to high volume usage warranty on production tools cannot be guaranteed due to unpredictable circumstances Tools are subjected to abuse such as hammering or usage of...

Page 4: ...t ten tuotteen vastaavan seuraavla standardeja ja direktiivej 2006 42 EC ja EN ISO 11148 13 2018 CE Dichiarazione di conformit EVERWIN PNEUMATIC CORP dichiara assumendo la piena responsabilit che ques...

Page 5: ...nsure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the emplo...

Page 6: ...f the arm is not working correctly as accidental driving of a fastener may result Do not interfere with the proper operation of the contact arm mechanism Do not drive fasteners on top of other fastene...

Page 7: ...and appropriate gloves and protective clothing are recommended Appropriate hearing protection shall be worn Use the correct energy supply as directed in the manual To drive fasteners into hard surface...

Page 8: ...pain throbbing aching tingling numbness burning sensation or stiffness do not ignore these warning signs The operator should consult a qualified health professional regarding overall activities Disco...

Page 9: ...3 6 2 9 kgs 6 4 lbs 2 9 kgs 6 4 lbs 3 08 liter second 6 5 cfm 3 08 liter second 6 5 cfm SPECIFICATIONS FASTENER SPECIFICATIONS TOOL AIR FITTING This tool uses a 3 8 19 P T 3 8 18 N P T male plug The i...

Page 10: ...stem when using the tool will for example depend on the gripping force the contact pressure force the working direction the adjustment of mains supply and the workpiece support AIR CONSUMPTION 3 08 li...

Page 11: ...p available system on SN65Q ST SN65S5 ST The Sequential Trip requires the operator to hold the tool against the work before pulling the trigger This makes accurate fastener placement easier for instan...

Page 12: ...l may fracture or burst causing injury OPERATING PRESSURE Do not exceed recommended maximum operating pressure as tool wear will be greatly increased The air supply must be capable of maintaining the...

Page 13: ...ulting in poor tool performance and frequent tool maintenance If no air line lubricator is used add oil during use into the air fitting on the tool once or twice a day Only a few drops of oil at a tim...

Page 14: ...EVENT ACCIDENTAL INJURIES Never place a hand or any other part of the body in the discharge area of tool while the air supply is connected Never point the tool at anyone else Never engage in horseplay...

Page 15: ...te the tool in this manner hold the tool with the contact trip pointing towards but not touching the work surface Pull the trigger and then tap the contact trip against the work surface using a bounci...

Page 16: ...eaks air or does not function properly Notify your distributor or representative if your tool continues to experience functional problems 1 Contact Trip Operation 2 Sequential Trip Operation a The too...

Page 17: ...toward the nose to increase the drive of depth deep Tighten screw with 4mm hex key The DEPTH OF DRIVE ADJUSTMENT feature provides close control of the fastener drive depth from flush with the work su...

Page 18: ...ME Air volume is as important as air pressure The air volume supplied to the tool may be inadequate because of undersize fittings and hoses or from the effects of dirt and water in the system Restrict...

Page 19: ...from the air supply 2 Pull pusher into its pusher lock position as shown remove staples from the magazine 3 Open the jam clearing nose door by pulling down and then up on the latch 4 Remove the jammed...

Page 20: ...20...

Reviews: