The troubleshooting and / or repairs shall be carried out only by the authorized dealer / distributor or by other
pneumatic tool specialists.
If a jam does occur, follow this procedure :
1. Disconnect the tool from the air supply.
2. Pull pusher into its pusher lock position as shown, remove staples from the magazine.
3. Open the jam clearing nose door by pulling down and then up on the latch.
4. Remove the jammed fastener.
5. Close the jam clearing nose door latch and release nail pusher back.
Always disconnect air supply before clearing a jammed fastener.
Jam-Clearing Procedure
TROUBLESHOOTING / REPAIRS
WARNING
19
Summary of Contents for SN65Q
Page 20: ...20...