The troubleshooting and / or repairs shall be carried out only by the authorized dealer / distributor or by other
pneumatic tool specialists.
If a jam occurs on the FN1850-CT, FN1850-ST, FN1850PAL, FS9240-CT, FS9240-ST, FS9240PAL, follow this procedure:
1. Disconnect the tool from the air supply.
2. Pull pusher into lock position or depress latch to pull magazine cover to open, remove remaining staples from the
magazine.
3. Open the jam clearing nose door by pulling down and then up on the latch.
4. Remove the jammed fastener.
5. Close the jam clearing nose door latch and release staple pusher back.
If a jam occurs on the FS9040-CT, FS9040-ST, FS9040PAL, follow this procedure:
1. Disconnect the tool from the air supply.
2. With the nose facing down, depress the latch and slide the magazine open.
3. The jammed staple along with remaining staples will fall out automatically.
Always disconnect air supply before clearing a jammed fastener.