background image

EYE PROTECTION

Which conforms to ANSI/ CE specifications and provides protection against flying particles both from 
the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when 
connecting to air supply, loading, operating, or servicing this tool. Eye protection is required to guard 
against flying fasteners and debris, which could cause severe eye injury. The employer and/or user must 
ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements 
of the ANSI Z87.1 and 89/686/EEC, and provide both frontal and side protection.

BEFORE HANDLING OR OPERATING THIS TOOL

Read and understand the warnings contained in this manual.

Refer to “tool specifications” in this manual to identify the operating system on your tool.

OPERATION : 

TOOL OPERATION SYSTEM

NOTE

Non-side shielded spectacles and face shields alone do not provide adequate protection.

There are three available systems in these tools :

1. Contact Trip Operation 

(available system on : FN1850-CT, FS9040-CT, FS9240-CT)

 

The CONTACT TRIP MODEL tool contains a contact trip that operates in conjunction with the trigger to drive a fastener. To 
operate the tool in this manner, hold the tool with the contact trip pointing towards but not touching the work surface. Pull 
the trigger and then tap the contact trip against the work surface using a bouncing motion. Each depression of the contact 
trip will cause a fastener to be driven.

2. Sequential Trip

 

Operation

 

(available system on : FN1850-ST, FS9040-ST, FS9240-ST)

 

 

The SEQUENTIAL TRIP MODEL contains a contact trip that operates in conjunction with the trigger to drive a fastener. 
To operate a sequential trip tool, first position the contact trip on the work surface WITHOUT PULLING THE TRIGGER. 
Depress the contact trip and then pull the trigger to drive a fastener. As long as the contact trip is contacting the work and 
is held depressed, the tool will drive a fastener each time the trigger is depressed. If the contact trip is allowed to leave the 
work surface, the sequence described above must be repeated to drive another fastener.

3. Remote Fire 

(available system on : FN1850PAL, FS9040PAL, FS9240PAL)

 

The REMOTE FIRE MODEL is cycle by actuation of remote valve (RCVA3-F & TVA2-F) for mounted machines.

The operator must not hold the trigger on contact trip tools except during fastening operation, as serious injury could result 
if the trip accidentally contacts someone or something, causing the tool to cycle.

Keep hands and body away from the discharge area of the tool. A contact trip tool may bounce from the recoil of driving a 
fastener and an unwanted second fastener may be driven, causing injury.

WARNING  

WARNING  

15

Summary of Contents for FN1850

Page 1: ...E MANUAL FN1850 FS9040 FS9240 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE...

Page 2: ...allation operation and maintenance should be read carefully and the manuals kept available for reference INTRODUCTION CE DECLARATION OF CONFORMITY SAFETY INSTRUCTIONS GENERAL SAFETY INSTRUCTION SPECIF...

Page 3: ...11148 13 2018 CE Declaracion de conformidad EVERWIN PNEUMATIC CORP declaramos bajo nuestra sola responsabilidad que este producto esta enconformidad con las Directivas Europeas 2006 42 EC y con la no...

Page 4: ...nsure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the emplo...

Page 5: ...f the arm is not working correctly as accidental driving of a fastener may result Do not interfere with the proper operation of the contact arm mechanism Do not drive fasteners on top of other fastene...

Page 6: ...nd appropriate gloves and protective clothing are recommended Appropriate hearing protection shall be worn Use the correct energy supply as directed in the manual To drive fasteners into hard surfaces...

Page 7: ...t pain throbbing aching tingling numbness burning sensation or stiffness do not ignore these warning signs The operator should consult a qualified health professional regarding overall activities Disc...

Page 8: ...5 8 1 9 16 1 25 x 1 00mm 0 049 x 0 039 8 6mm 5 16 259mm 10 2 100 60mm 2 4 1 4 kgs 3 1 lbs 0 8 liter second 1 69 cfm SPECIFICATIONS AND TECHNICAL DATA SPECIFICATIONS FASTENER SPECIFICATIONS TOOL AIR F...

Page 9: ...essure force the working direction the adjustment of mains supply and the workpiece support SPECIFICATIONS AND TECHNICAL DATA AIR CONSUMPTION 0 8 liter sec 1 69 cfm of free air to operate at the rate...

Page 10: ...RCVA3 F TVA2 F 2 Sequential Trip available system on FN1850 ST FS9040 ST FS9240 ST The Sequential Trip requires the operator to hold the tool against the work before pulling the trigger This makes acc...

Page 11: ...l may fracture or burst causing injury OPERATING PRESSURE Do not exceed recommended maximum operating pressure as tool wear will be greatly increased The air supply must be capable of maintaining the...

Page 12: ...ulting in poor tool performance and frequent tool maintenance If no air line lubricator is used add oil during use into the air fitting on the tool once or twice a day Only a few drops of oil at a tim...

Page 13: ...worn Eye protection equipment must conform to the requirements of the ANSI Z87 1 and 89 686 EEC and provide both frontal and side protection TO PREVENT ACCIDENTAL INJURIES Never place a hand or any ot...

Page 14: ...to notch on the top of magazine assembly Load Fastener Load Fastener Load Fastener Insert nails into track of magazine Hold the stapler upside down and place staples in the bottom channel Drop staple...

Page 15: ...s but not touching the work surface Pull the trigger and then tap the contact trip against the work surface using a bouncing motion Each depression of the contact trip will cause a fastener to be driv...

Page 16: ...eaks air or does not function properly Notify your distributor or representative if your tool continues to experience functional problems 1 Contact Trip Operation 2 Sequential Trip Operation a The too...

Page 17: ...IR PRESSURE AND VOLUME Air volume is as important as air pressure The air volume supplied to the tool may be inadequate because of undersize fittings and hoses or from the effects of dirt and water in...

Page 18: ...les from the magazine 3 Open the jam clearing nose door by pulling down and then up on the latch 4 Remove the jammed fastener 5 Close the jam clearing nose door latch and release staple pusher back If...

Page 19: ...19...

Page 20: ...20...

Reviews: