OPERATION : LUBRICATION

Cold Weather Operation

For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool operation. We 

recommend the use of permanent antifreeze (ethylene glycol) as a cold weather lubricant.

Frequent, but not excessive, lubrication is required for best performance. Air - tool oil added through the air line connection 
will lubricate the internal parts. Do not use detergent oil or additives as these lubricants will cause accelerated wear to the 
seals and bumpers in the tool, resulting in poor tool performance and frequent tool maintenance.

If no air line lubricator is used, add oil during use into the air fitting on the tool once or twice a day. Only a few drops of oil at 
a time is necessary. Too much oil will only collect inside the tool and will be noticeable in the exhaust cycle.

NOTE

Some commercial air line drying liquids are harmful to O-Rings and seals – do not use these low temperature air dryers 
without checking compatibility.

CAUTION 

Do not store tools in a cold-weather environment to prevent frost or ice formation on the tools operating valves and 
mechanisms, which could cause tool failure. Test tool without fasteners prior to operations to ensure no malfunction on the 
tool due to ice formation.

12

Summary of Contents for FN1850

Page 1: ...E MANUAL FN1850 FS9040 FS9240 BEFORE OPERATING THIS TOOL ALL OPERATORS SHOULD READ AND STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE...

Page 2: ...allation operation and maintenance should be read carefully and the manuals kept available for reference INTRODUCTION CE DECLARATION OF CONFORMITY SAFETY INSTRUCTIONS GENERAL SAFETY INSTRUCTION SPECIF...

Page 3: ...11148 13 2018 CE Declaracion de conformidad EVERWIN PNEUMATIC CORP declaramos bajo nuestra sola responsabilidad que este producto esta enconformidad con las Directivas Europeas 2006 42 EC y con la no...

Page 4: ...nsure that any necessary hearing protection is provided and used by the operator and others in the work area Some environments will require the use of head protection equipment When required the emplo...

Page 5: ...f the arm is not working correctly as accidental driving of a fastener may result Do not interfere with the proper operation of the contact arm mechanism Do not drive fasteners on top of other fastene...

Page 6: ...nd appropriate gloves and protective clothing are recommended Appropriate hearing protection shall be worn Use the correct energy supply as directed in the manual To drive fasteners into hard surfaces...

Page 7: ...t pain throbbing aching tingling numbness burning sensation or stiffness do not ignore these warning signs The operator should consult a qualified health professional regarding overall activities Disc...

Page 8: ...5 8 1 9 16 1 25 x 1 00mm 0 049 x 0 039 8 6mm 5 16 259mm 10 2 100 60mm 2 4 1 4 kgs 3 1 lbs 0 8 liter second 1 69 cfm SPECIFICATIONS AND TECHNICAL DATA SPECIFICATIONS FASTENER SPECIFICATIONS TOOL AIR F...

Page 9: ...essure force the working direction the adjustment of mains supply and the workpiece support SPECIFICATIONS AND TECHNICAL DATA AIR CONSUMPTION 0 8 liter sec 1 69 cfm of free air to operate at the rate...

Page 10: ...RCVA3 F TVA2 F 2 Sequential Trip available system on FN1850 ST FS9040 ST FS9240 ST The Sequential Trip requires the operator to hold the tool against the work before pulling the trigger This makes acc...

Page 11: ...l may fracture or burst causing injury OPERATING PRESSURE Do not exceed recommended maximum operating pressure as tool wear will be greatly increased The air supply must be capable of maintaining the...

Page 12: ...ulting in poor tool performance and frequent tool maintenance If no air line lubricator is used add oil during use into the air fitting on the tool once or twice a day Only a few drops of oil at a tim...

Page 13: ...worn Eye protection equipment must conform to the requirements of the ANSI Z87 1 and 89 686 EEC and provide both frontal and side protection TO PREVENT ACCIDENTAL INJURIES Never place a hand or any ot...

Page 14: ...to notch on the top of magazine assembly Load Fastener Load Fastener Load Fastener Insert nails into track of magazine Hold the stapler upside down and place staples in the bottom channel Drop staple...

Page 15: ...s but not touching the work surface Pull the trigger and then tap the contact trip against the work surface using a bouncing motion Each depression of the contact trip will cause a fastener to be driv...

Page 16: ...eaks air or does not function properly Notify your distributor or representative if your tool continues to experience functional problems 1 Contact Trip Operation 2 Sequential Trip Operation a The too...

Page 17: ...IR PRESSURE AND VOLUME Air volume is as important as air pressure The air volume supplied to the tool may be inadequate because of undersize fittings and hoses or from the effects of dirt and water in...

Page 18: ...les from the magazine 3 Open the jam clearing nose door by pulling down and then up on the latch 4 Remove the jammed fastener 5 Close the jam clearing nose door latch and release staple pusher back If...

Page 19: ...19...

Page 20: ...20...

Reviews: