background image

Frame Manual 

500FR 3 Rack Unit Frame  

500FR-2

 Revision 

1.4

 

1.1. SPECIFICATIONS 

1.1.1. Electrical 

AC Mains Input

 

Auto ranging, 100 

Ù

 240 VAC, 50/60 Hz 

Maximum Operating Current: 

2.6 A (@ 120 VAC), 1.4 A (@ 240 VAC) 

Maximum Power Consumption:

 200 

Maximum Module Load:

 

160 W (10 W per slot) 

Power Supply Configuration

 

Dual, redundant, separate AC inlets 

Connector:

 

IEC 60320 - 1 per power supply 

Fuses:

 

4 amp, 250 volt time delay 5 x 20 mm. – 2 per power supply 

Safety:

 

CSA Listed to CSA C22.2 No. 60065-03, UL 60065-03 
IEC 60065-(2001-12) 7th Edition 

 

Complies with CE Low voltage Directive 93/68/EEC 

EMC:

 

Complies with FCC part 15, class A. 

 

Complies with EU EMC directive 89/336/EEC 

Status Indicators:

 

PSU status LED 

 

Local Error/Failure LED 

Tally Output Connector: 

4 pin terminal, relay N/O, N/C for status/fault alarm, 2 A, 125 VDC max

 

Temperature:

 

0 - 40

°

C  

 

1.1.2. Physical 

Height:

 

5.25” (133 mm) 

Width:

 

19” (483 mm) 

Depth:

 

9.5” (368 mm) 

Module Capacity:

 16 

slots 

Weight:

 

Approx 17 lbs (7.7 Kg) with 2 power supplies, no slots occupied 

 

Approx. 32 lbs. (14.5 Kg) with 2 power supplies all slots occupied 

 

1.2. COOLING 

The 500FR frame is designed to ensure adequate cooling for up to 120 watts of processing power per 
frame.  Fans at the front and rear of each power supply module accomplish forced air cooling.  Adjacent 
equipment may be mounted immediately to the top and bottom of the 500FR frame.  Additional module 
cooling is provided by interior cooling channels to ensure that even fully loaded frames mounted adjacent 
to each other will operate within the normal temperature range.   
 

 

For proper cooling, the frame must contain either two 500PS power supplies, or 
one 500PS power supply and one 500PS-FM power supply blank panel with cooling 
fan. 

 

Summary of Contents for exponent 500FR

Page 1: ...2 FRAME STATUS FAULT CONDITIONS 5 2 1 FRAME STATUS TALLY TERMINAL BLOCK 5 3 INSTALLING AND REMOVING THE MODULES 5 3 1 OPENING AND CLOSING THE FRONT PANEL 5 3 2 INSTALLING THE MODULES 6 3 3 REMOVING THE MODULES 6 4 SERVICING INSTRUCTIONS 6 4 1 CHANGING THE FUSES 6 4 2 REPLACING THE POWER SUPPLY 6 Figures Figure 1 500PS Status Indicators 4 Figure 2 Locating the Power Supply Mounting Screw 7 Tables T...

Page 2: ...n this document concerning performance of Evertz products are for informational use only and are not warranties of future performance either express or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features install...

Page 3: ...in different versions to suit a variety of applications Throughout this manual references to 500FR refer to all models of the frame unless otherwise specified Model Description 500FR AC powered frame This frame supports all 500 series modules EXCEPT analog or digital loop through modules 500FR L A AC powered frame with loop thru capability for analog video signal This frame supports ONLY analog lo...

Page 4: ...rminal relay N O N C for status fault alarm 2 A 125 VDC max Temperature 0 40 C 1 1 2 Physical Height 5 25 133 mm Width 19 483 mm Depth 9 5 368 mm Module Capacity 16 slots Weight Approx 17 lbs 7 7 Kg with 2 power supplies no slots occupied Approx 32 lbs 14 5 Kg with 2 power supplies all slots occupied 1 2 COOLING The 500FR frame is designed to ensure adequate cooling for up to 120 watts of processi...

Page 5: ...atically senses the input voltage An additional power supply 500PS can be ordered to provide fully redundant powering of the frame When only one power supply is fitted the frame will be fitted with a 500PS FM fan module to ensure the thermal integrity of the frame cooling Power should be applied by connecting a 3 wire grounding type power supply cord to the power entry module on the rear panel of ...

Page 6: ...e status buss fault conditions If one of the power supplies malfunctions power cord disconnected power switch is off fuse is blown rear fan is stopped etc then its PSU STATUS LED will go Off and the red FRAME STATUS LED on both power supplies will turn On If the power supplies are fitted with green FRAME STATUS LEDs they will turn Off The PSU STATUS LED on the power supply that is functioning will...

Page 7: ...f the Frame Status Jumper on the module consult the individual chapter for the module For example if a module requires video or audio for its functionality and the video or audio is not present the red LOCAL FAULT LED on the module will be On and the fault will be reported on the frame status buss if the FRAME STATUS jumper on the module is set to the On position default 2 1 FRAME STATUS TALLY TER...

Page 8: ... is located inside the power entry module To change the fuses pull out the fuse holder from the power entry module using a small screwdriver The fuse holder contains two fuses one for the line and one for the neutral side of the mains connection Pull out the blown fuse and place a fuse of the correct value in its place Use time delay 5 x 20 mm fuses rated for 250 Volts with a current rating of 4 a...

Page 9: ...th only one power supply a 500PS FM blank power supply module with cooling fan must be inserted into the second power supply space The 500PS FM contains a module cooling fan and baffles to maintain proper airflow within the frame The power supply is secured into the frame by a machine screw through the rear panel as shown in Figure 2 This screw must be removed before the power supply can be extrac...

Page 10: ...he power supply mounting screw 4 Open the front door of the frame and pull the power supply out of the frame 5 Reinsert the new power supply into the frame taking care that it is proper aligned with the card guides Press firmly to make sure that the power supply is fully seated into the rear panel connector 6 Reinstall the power supply mounting screw from the rear of the frame 7 Turn on the power ...