Frame Manual
500FR 3 Rack Unit Frame
500FR-2
Revision
1.4
1.1. SPECIFICATIONS
1.1.1. Electrical
AC Mains Input
Auto ranging, 100
Ù
240 VAC, 50/60 Hz
Maximum Operating Current:
2.6 A (@ 120 VAC), 1.4 A (@ 240 VAC)
Maximum Power Consumption:
200
W
Maximum Module Load:
160 W (10 W per slot)
Power Supply Configuration
Dual, redundant, separate AC inlets
Connector:
IEC 60320 - 1 per power supply
Fuses:
4 amp, 250 volt time delay 5 x 20 mm. – 2 per power supply
Safety:
CSA Listed to CSA C22.2 No. 60065-03, UL 60065-03
IEC 60065-(2001-12) 7th Edition
Complies with CE Low voltage Directive 93/68/EEC
EMC:
Complies with FCC part 15, class A.
Complies with EU EMC directive 89/336/EEC
Status Indicators:
PSU status LED
Local Error/Failure LED
Tally Output Connector:
4 pin terminal, relay N/O, N/C for status/fault alarm, 2 A, 125 VDC max
Temperature:
0 - 40
°
C
1.1.2. Physical
Height:
5.25” (133 mm)
Width:
19” (483 mm)
Depth:
9.5” (368 mm)
Module Capacity:
16
slots
Weight:
Approx 17 lbs (7.7 Kg) with 2 power supplies, no slots occupied
Approx. 32 lbs. (14.5 Kg) with 2 power supplies all slots occupied
1.2. COOLING
The 500FR frame is designed to ensure adequate cooling for up to 120 watts of processing power per
frame. Fans at the front and rear of each power supply module accomplish forced air cooling. Adjacent
equipment may be mounted immediately to the top and bottom of the 500FR frame. Additional module
cooling is provided by interior cooling channels to ensure that even fully loaded frames mounted adjacent
to each other will operate within the normal temperature range.
For proper cooling, the frame must contain either two 500PS power supplies, or
one 500PS power supply and one 500PS-FM power supply blank panel with cooling
fan.