evertz exponent 500FR Manual Download Page 7

Frame Manual 

500FR 3 Rack Unit Frame 

 Revision 

1.4 

500FR-5 

2. 

FRAME STATUS FAULT CONDITIONS 

The Frame is fitted with a global Frame Status monitoring buss that is connected to each of the power 
supplies and to each of the modules.  When a fault condition occurs on one of the power supplies, or one 
of the modules, a Frame Status Fault condition is active on the frame status buss.  When this occurs the 
red FRAME STATUS LED on the power supply will come on and the relay on the Frame Status Tally 
terminal block will activate.  
 
Power supplies, will assert a frame status fault when their PSU STATUS LED is off.   
 
Each module has a large red LOCAL FAULT LED and a large green MODULE OK LED at the top of the 
card edge.  This green LED indicates good module health while the red LED indicates that there is a fault 
condition on the module.  Each module has its own criteria that determines when the red fault LED comes 
on. When the red LOCAL FAULT LED is On the module can also assert a fault condition on the Frame 
Status buss.  On each module there is a jumper that disables sending local card fault information to the 
Frame Status Buss.  For more information about fault conditions on individual modules, and for the 
location of the Frame Status Jumper on the module consult the individual chapter for the module.  For 
example, if a module requires video or audio for its functionality and the video or audio is not present, the 
red LOCAL FAULT LED on the module will be On and the fault will be reported on the frame status buss if 
the FRAME STATUS jumper on the module is set to the On position (default). 
 

2.1. 

FRAME STATUS TALLY TERMINAL BLOCK 

There is a green 

FRAME STATUS 

terminal block at the rear of the frame that has a normally open and 

normally closed relay contact that can be used to indicate frame status fault conditions to external 
equipment.  There are 4 connections. 
 

Label Pin 

Function 

Chassis Ground (connect to cable shield) 

Common (connect to Ground or your reference) 

Open with respect to common when Frame Status fault exists 

Closed with respect to common when Frame Status fault exists 

Table 1: Frame Status Tally Terminal Block Pin Assignments 

The relay contacts can sink up to 2A and operate up to 125 VDC. 
 

3. 

INSTALLING AND REMOVING THE MODULES 

3.1. 

OPENING AND CLOSING THE FRONT PANEL 

In order to insert or remove modules you will have to open the front panel.  Turn the two captive screws 
located on the front panel counter clockwise several turns until they release completely from the front 
extrusions.  Carefully lower the front panel door so that the front edge of the door is lower than the rear of 
the door.   
 

Summary of Contents for exponent 500FR

Page 1: ...2 FRAME STATUS FAULT CONDITIONS 5 2 1 FRAME STATUS TALLY TERMINAL BLOCK 5 3 INSTALLING AND REMOVING THE MODULES 5 3 1 OPENING AND CLOSING THE FRONT PANEL 5 3 2 INSTALLING THE MODULES 6 3 3 REMOVING THE MODULES 6 4 SERVICING INSTRUCTIONS 6 4 1 CHANGING THE FUSES 6 4 2 REPLACING THE POWER SUPPLY 6 Figures Figure 1 500PS Status Indicators 4 Figure 2 Locating the Power Supply Mounting Screw 7 Tables T...

Page 2: ...n this document concerning performance of Evertz products are for informational use only and are not warranties of future performance either express or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features install...

Page 3: ...in different versions to suit a variety of applications Throughout this manual references to 500FR refer to all models of the frame unless otherwise specified Model Description 500FR AC powered frame This frame supports all 500 series modules EXCEPT analog or digital loop through modules 500FR L A AC powered frame with loop thru capability for analog video signal This frame supports ONLY analog lo...

Page 4: ...rminal relay N O N C for status fault alarm 2 A 125 VDC max Temperature 0 40 C 1 1 2 Physical Height 5 25 133 mm Width 19 483 mm Depth 9 5 368 mm Module Capacity 16 slots Weight Approx 17 lbs 7 7 Kg with 2 power supplies no slots occupied Approx 32 lbs 14 5 Kg with 2 power supplies all slots occupied 1 2 COOLING The 500FR frame is designed to ensure adequate cooling for up to 120 watts of processi...

Page 5: ...atically senses the input voltage An additional power supply 500PS can be ordered to provide fully redundant powering of the frame When only one power supply is fitted the frame will be fitted with a 500PS FM fan module to ensure the thermal integrity of the frame cooling Power should be applied by connecting a 3 wire grounding type power supply cord to the power entry module on the rear panel of ...

Page 6: ...e status buss fault conditions If one of the power supplies malfunctions power cord disconnected power switch is off fuse is blown rear fan is stopped etc then its PSU STATUS LED will go Off and the red FRAME STATUS LED on both power supplies will turn On If the power supplies are fitted with green FRAME STATUS LEDs they will turn Off The PSU STATUS LED on the power supply that is functioning will...

Page 7: ...f the Frame Status Jumper on the module consult the individual chapter for the module For example if a module requires video or audio for its functionality and the video or audio is not present the red LOCAL FAULT LED on the module will be On and the fault will be reported on the frame status buss if the FRAME STATUS jumper on the module is set to the On position default 2 1 FRAME STATUS TALLY TER...

Page 8: ... is located inside the power entry module To change the fuses pull out the fuse holder from the power entry module using a small screwdriver The fuse holder contains two fuses one for the line and one for the neutral side of the mains connection Pull out the blown fuse and place a fuse of the correct value in its place Use time delay 5 x 20 mm fuses rated for 250 Volts with a current rating of 4 a...

Page 9: ...th only one power supply a 500PS FM blank power supply module with cooling fan must be inserted into the second power supply space The 500PS FM contains a module cooling fan and baffles to maintain proper airflow within the frame The power supply is secured into the frame by a machine screw through the rear panel as shown in Figure 2 This screw must be removed before the power supply can be extrac...

Page 10: ...he power supply mounting screw 4 Open the front door of the frame and pull the power supply out of the frame 5 Reinsert the new power supply into the frame taking care that it is proper aligned with the card guides Press firmly to make sure that the power supply is fully seated into the rear panel connector 6 Reinstall the power supply mounting screw from the rear of the frame 7 Turn on the power ...

Reviews: