570J2K-HW-X19
Multi channel J2K Encoder-Decoder
Revision 1.0
Page - 5
2.3.
HARDWARE INSTALLATION
To successfully install the 570J2K-HW-X19, the following is required:
1. 570 Series Frame
2. 570 Frame Controller
3. WebEASY
®
using the 570FC frame controller with 570J2K-HW-X19 installed in frame.
Before handling the card it is important to minimize the potential effects of static electricity. It is
therefore recommended that an ESD strap be worn.
Locate on the chassis 2 adjacent vacant slots. Unpack the 570J2K-HW-X19 and separate the rear
panel from the main card. Locate on the rear of the rack the two slots and remove the blanking panels.
Insert the rear panel into the back of the chassis and secure using the four screws provided.
Now insert the 570J2K-HW-X19 card into the corresponding front slots ensuring the card lines up with
the slot runners on the bottom and the top of the chassis. Push the card
firmly
into the slot ensuring
that when it mates with the rear card it has been firmly pushed into a seated position. Do not connect
any cables to the rear card (failure to do this could cause unwanted network issues) until the initial
configuration has been completed.
This procedure can be completed to all the other modules and is hot swappable allowing for the frame
to be powered on while installing.
2.4.1 CONNECTION VIA FC PROXY
The control of the 570J2K-HW-X19 can be done through FC Proxy. To configure a FC Proxy address
for the 570J2K-HW-X19, log into the 570FC webpage using “root” and “evertz” for the username and
password respectively. Navigate to the slot that houses the 570J2K-HW-X19 and enable the Proxy
Mode Address. Configure the Address, Netmask and Gateway for the required Control Connection.
Note the Proxy address must be configured for the second slot that 570J2K-HW-X19 occupies (i.e. if it
is placed in slot 2 and 3, configure proxy address for slot 3).
Figure
2-2 : 570FC Proxy Address