NAV IP Access controller
111
when
a
card
is
swiped
at
any
door
at
which
it
does
not
have
the
right
to
pass.
The
controller
generates
alarm
output(s)
according
to
the
setting
in
the
“Invalid
Door”
column.
Invalid
Time:
Each
card
belongs
to
an
access
group.
For
each
group,
the
system
can
assign
access
rights
to
certain
doors
for
certain
time
zones.
An
invalid
time
event
will
be
generated
if
a
card
is
swiped
during
a
time
period
in
which
it
does
not
have
the
right
to
pass.
The
controller
generates
alarm
output(s)
according
to
the
setting
in
the
“Invalid
Time”
column.
APB
Fail:
If
the
card
APB
property
is
enabled,
and
door
behavior
under
APB
is
set
to
“unlock”.
A
cardholder
will
be
able
to
enter/exit
any
doors
by
swiping
the
card.
The
system
generates
an
APB
fail
event
if
an
APB
event
is
triggered.
The
controller
generates
alarm
output(s)
according
to
the
setting
in
the
“APB
Fail”
column.
Card
PIN
Fail:
A
card
PIN
fail
event
is
generated
when
a
PIN
‐
enabled
card
is
presented
at
a
reader
and
an
incorrect
PIN
is
entered
three
times
consecutively.
The
controller
generates
alarm
output(s)
according
to
the
setting
in
the
“Card
PIN
Fail”
column.
Door
Forced
Open:
A
door
forced
open
event
is
generated
when
the
door
sensor
indicates
to
the
controller
that
a
door
is
opened,
but
no
legitimate
card
has
been
presented
and
a
Request
‐
to
‐
Exit
button
has
not
been
pressed.
The
controller
generates
alarm
output(s)
according
to
the
setting
in
the
“Door
Forced
Open”.
In
practice,
a
door
forced
open
event
will
be
generated
if
a
door
is
kicked
open.
Door
endures
Open:
A
door
endures
open
event
is
generated
if
a
cardholder
enters
endures
PIN
to
unlock
a
door
when
under
endures.
The
controller
generates
alarm
output(s)
according
to
the
setting
in
the
“Door
endures
Open”.
Door
Held
Open/Overtime:
the
system
keeps
tracking
of
the
door
status
when
a
card
is
presented
to
a
reader
or
Request
‐
to
‐
Exit
button
is
pressed.
A
door
held
open/overtime
event
occurs
when
a
door
is
held
open
for
longer
than
the
allowed
door
held
open
time.
The
controller
generates
alarm
output(s)
according
to
the
setting
in
the
“Door
Held
Open”
column.
Reader
Lost:
A
reader
lost
event
is
generated
when
the
controller
detects
that
the
card
reader
appears
to
have
been
disconnected
from
the
system.
The
controller
generates
alarm
output(s)
according
to
the
setting
in
the
“Reader
Lost”
column.
Panic
door:
When
an
access
denied
appears
and
request
open
did
not
implement,
however,
door
magnetic
sensor
is
displayed
the
door
have
been
opened,
it
will
lead
a
“panic
door”
event.
The
controller
generates
alarm
output(s)
according
to
the
setting
in
the
“Panic
Door”
column.
Steps:
1)
Click
the
“Alarm
Action”
tab
page
2)
Select
an
alarm
to
be
set
in
alarm
list.
3)
In
the
corresponding,
click
the
position
to
show
drop
‐
down
menu
of
alarm
output,
select
the
output
value:
R,
Y,
N.
4)
Click
the
“Save”
button
to
save
your
changes.
12.1.5.5 Alarm Time
On
the
alarm
time
setting
page,
users
can
set
the
alarm
time
for
the
specified
controller.