59
HD Temperature:
Figure 4-13 Alarm & Event Menu – Event - HD Temperature
Log:
Check box to record HDD temperature events in the log.
Buzzer:
Check box to enable buzzer when hard drive’s temperature is over the “Temp. Warning Limit”.
Email Notify:
Check box to enable email notification when HDD temperature is over the “Temp. Warning
Limit”. Email operation requires that valid email settings have been entered in the Network Setting/Email
setup screen.
Network Alarm:
Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Stop Recording:
Check box to stop recording when HD’s temperature is over the “Temp. Warning Limit”.
Temp. Warning Limit:
Sets the trigger temperature for HD Temperature event actions. Choose between
55
°
C /131
°
F or 85
°
C /185
°
F.
Alarm Output:
This will transmit a signal through the alarm output. It can be set to either “
NONE
” (not
active) “
1
” (active) or, “
2
” (active).
Output Type:
Output action will be
Transparent
and cannot be changed (alarm output remains as long as
the alarm condition is active).