51
alarm output according to this setting. By default, only the Main alarm output on
main module has alarm output per Fire Alarm event, as shown in the following two
figures. Change settings according to sections “Enter Alarm Action Setting Sub-
menu” and “Enter Extended Alarm Setting Sub-menu”.
Zone Alarm 1~8
Zone alarm reacts to 8 alarm inputs on alarm module. Zone alarm should be
triggered when any alarm event occurs in any arm zone. The default setting for Alarm
Action Setting and Extended Alarm Setting per Zone Alarm event is shown in the
following two figures, respectively. Change settings according to sections “Enter
Alarm Action Setting Sub-menu” and “Enter Extended Alarm Setting Sub-menu”.
SYS PIN Fail
Please refer to section
“
Gain Access to System Configuration
”
in this chapter. A SYS
PIN Fail event will be generated when user enters the PIN to enter system setting
and a wrong PIN is entered three times consecutively. The default setting for Alarm
Action Setting and Extended Alarm Setting is: only Main alarm output on main
module has alarm output per SYS PIN fail event, as shown in the following two
figures, respectively. Change settings according to sections “Enter Alarm Action
Setting Sub-menu” and “Enter Extended Alarm Setting Sub-menu”.
ARM PIN Fail
User is required to enter PIN when pressing ARM key to arm or disarm the system.
An ARM PIN Fail event will be generated when a wrong PIN is entered three times
consecutively. For how to arm/disarm the system, please refer to later section
“ARM/DISARM”. The default setting for Alarm Action Setting and Extended
Alarm Setting is: only Main alarm output on main module has alarm output per ARM
PIN fail event, as shown in the following two figures, respectively. Change settings
according to sections “Enter Alarm Action Setting Sub-menu” and “Enter Extended
Alarm Setting Sub-menu”.
ARM PIN Fail
NNNNNNNN
SYS PIN Fail
NNNNNNNN-YN
SYS PIN Fail
NNNNNNNN
Zone-1 Alarm
NNNNNNNN
Zone-1 Alarm
NNNNNNNN-NN
Fire Alarm
NNNNNNNN
Fire Alarm
NNNNNNNN-YN
ARM PIN Fail
NNNNNNNN-YN
Summary of Contents for EFC-02-1A