EVCO S.p.A.
Vcolor 818
| Installer manual ver. 1.1 | Code 144VC818E114
page 27 of 94
4.1
Press and release the MENU key and then press and release the key (4) or the key (5) to select the blast
chilling duration and the work set-point during blast chilling.
4.2
Press and release the key + (6) or the key – (7) to modify these values and then the ESCAPE key to memorise
them; these values can also be memorised through parameters r1 and r7.
5.
Press and release the START/STOP key (1): the cycle will be started.
During blast chilling the device displays the residual blast chilling time, the temperature of the cabinet, the name of
the program (if envisioned) and the time passed from the start of blast chilling.
Operate as indicated to stop the cycle:
6.
Press and hold the START/STOP key 3 s.
The successive parameters establish the following values:
-
parameter r1 establishes blast chilling duration
-
parameter r7 establishes the work set-point during blast chilling.
On expiry of the blast chilling duration, the device automatically passes to storage mode and the buzzer is activated
for the time period established with parameter AA.
Press and release a key to silence the buzzer.