EVCO S.p.A.
Vcolor 818
| Installer manual ver. 1.1 | Code 144VC818E114
page 22 of 94
6.2
Temperature-controlled blast chilling and storage
The temperature-controlled blast chilling and storage cycle is divided into the following two phases:
-
blast chilling
-
storage.
On conclusion of a phase, the device passes automatically to the next.
Operate as indicated to start the cycle:
1.
Make sure the device is in the "on" status.
2.
Make sure that the keyboard is not locked and that no procedure is in progress.
3.
Press and release the key (1);
4.
Press and release the key (2) and then press and release the key (3). the device will display the blast chilling
end temperature and the work set-point during blast chilling.
4.1
Press and release the MENU key and then press and release the key (4) or the key (5) to select the blast
chilling end temperature and the work set-point during blast chilling.
4.2
Press and release the key + (6) or the key – (7) to modify these values and then the ESCAPE key to memorise
them; these values can also be memorised through parameters r3 and r7.
5.
Press and release the START/STOP key (1): the test to verify the correct insertion of the needle probe will be
started; see paragraph 6.14 " Test for verification of the correct insertion of the needle probe".