EVJ 700

EVJ 700

EVJ 700

EVJ 700    

Application Manual: 

Controller for horizontal cooking 
modules 

 

||||    

4 cooking combinations (depending on the application): 
power or tempe timer or needle probe 

||||    

ON-OFF or PI temperature control 

||||

 

Models for managing external SSRs 

||||    

Push encoder and/or 6 capacitive 
touch keys 

||||

 

2.8” LCD colour graphic display 

||||    

IP65 front protection 

||||    

2 installation methods on front panel: built-in 
or concealed under the panel 
(if made of glass or methacrylate) with customizable 
keys on the panel surface 

Summary of Contents for EVJ 700

Page 1: ...plication power or temperature timer or needle probe ON OFF or PI temperature control Models for managing external SSRs Push encoder and or 6 capacitive touch keys 2 8 LCD colour graphic display IP65 front protection 2 installation methods on front panel built in or concealed under the panel if made of glass or methacrylate with customizable keys on the panel surface ...

Page 2: ...ecautions before using the device Only use the device in the ways described in this document CONSIDER THE ENVIRONMENT CONSIDER THE ENVIRONMENT CONSIDER THE ENVIRONMENT CONSIDER THE ENVIRONMENT Keep this document with the device for future reference Please do not print out again DISPOSAL DISPOSAL DISPOSAL DISPOSAL The device must be disposed of according to local regulations governing the collectio...

Page 3: ...2 2 2 Introduction 12 Keypad 12 Push encoder 12 Changing values 13 Power failure 13 Communication 13 Basic functions 14 Fans 14 Heating 14 Activating the buzzer when the setpoint is reached 14 Main menu Main menu Main menu Main menu 1 1 1 15 5 5 5 Configuration screen 15 Setting password 15 Available menus 16 Configuration 16 Service 16 Language 16 Internal values 16 Restoring parameters 15 Config...

Page 4: ...arie 40 List of alarms List of alarms List of alarms List of alarms 4 4 4 42 2 2 2 Table of alarms 42 Parameters Parameters Parameters Parameters 4 4 4 43 3 3 3 Managing parameters 43 Making changes using the EVJKEY 43 Table of parameters 44 Technical specifications Technical specifications Technical specifications Technical specifications 4 4 4 49 9 9 9 ...

Page 5: ... cookers bain marie and grills Depending on the application cooking can be controlled by power or temperature combined with a timer or needle probe as required Temperature can be ON OFF or PI controlled for greater regulation precision The smart 2 8 inch LCD graphic display with 6 capacitive touch keys and or a push encoder provides constant information about the processes in progress as well as m...

Page 6: ...puts Digital inputs Multi purpose 1 Multi purpose 2 Digital outputs electro Digital outputs electro Digital outputs electro Digital outputs electro mechanical relays A res mechanical relays A res mechanical relays A res mechanical relays A res at 250 VAC at 250 VAC at 250 VAC at 250 VAC Load 1 configurable 16 A 16 A 16 A 16 A Load 2 configurable 5 A 8 A 5 A Load 4 configurable 8 A 8 A 8 A 8 A Load...

Page 7: ...d 3 4 mm 1 32 and 1 8 in INSTALLATION PRECAUTIONS INSTALLATION PRECAUTIONS INSTALLATION PRECAUTIONS INSTALLATION PRECAUTIONS Ensure that the working conditions are within the limits stated in the Technical specifications section Do not install the device close to heat sources equipment with a strong magnetic field in places subject to direct sunlight rain damp excessive dust mechanical vibrations ...

Page 8: ...rature of between 15 and 38 C 59 and 100 F for about an hour before carrying out the installation before installation carefully clean the panel surface that will be in contact with the double sided adhesive tape making sure that the product used for cleaning is suitable for the panel material we recommend using isopropyl alcohol in the case of surfaces greased with a hydrocarbon solvent Continue c...

Page 9: ...lectromagnetic interference locate the power cables as far away as possible from the signal cables If using an electrical or pneumatic screwdriver adjust the tightening torque If the device is moved from a cold to a warm place humidity may cause condensation to form inside wait for about an hour before switching on the power Make sure that the supply voltage electrical frequency and power are with...

Page 10: ...EVJ 700 EVJ 700 EVJ 700 EVJ 700 Application Manual 144EVJ700E204 EVCO 29 01 2021 10 Electrical connection model EVJ705J9 and EVJ705J9VG ...

Page 11: ...EVJ 700 EVJ 700 EVJ 700 EVJ 700 Application Manual 144EVJ700E204 EVCO 29 01 2021 11 Electrical connection model EVJ725J9 ...

Page 12: ...controller on off REFRESH At the end of the countdown pressing this key will refresh the time previously set on the selected timer FUNCTION Depending on the application activated the four function keys are used to select type of cooking temperature setpoint heating power cooking time Once the function has been selected e g the timer the relative icon goes from grey to white as does the value which...

Page 13: ... The value will become white Turn the encoder to set the value and press the push button once again to confirm If neither of these two procedures are carried out within 5 seconds the controller will automatically save the displayed value The display will return to the ON screen Function Select the function VALUE change the value using the SET keys Power failure Power failure Power failure Power fa...

Page 14: ...rd probe or there is a probe error the relay will always be active When the heating output is active either in power controlled and in temperature controlled models the icon will be displayed in the top left corner Heating When regulation is managed with a temperature setpoint the relay output for the heaters can be managed by conventional or PI type regulation Activating the buzzer when the setpo...

Page 15: ...on keys corresponding to the UP and DOWN arrows The writing will become white when selected Press the SET function key to confirm Setting the password Some of the menus in the configuration screen require a password to be entered to be changed Configuration allows the user to configure the type of application to be managed by the controller Service manages the parameters Restore parameters reloads...

Page 16: ...ir labels descriptions and values can be found in the section Table of parameters After entering the password the complete list of parameters will appear on the screen The parameters to change can be selected by pressing the function keys corresponding to the UP and DOWN arrows and then the SET function key to confirm Language The required language can be chosen in this menu Italian English French...

Page 17: ...G HEATING ELEMENT ELEMENT ELEMENT ELEMENT HEATING HEATING HEATING HEATING ELEMENT ELEMENT ELEMENT ELEMENT TOP HEATING TOP HEATING TOP HEATING TOP HEATING ELEMENT ELEMENT ELEMENT ELEMENT K2 K2 K2 K2 H H H H2 2 2 2O O O O CHARGE CHARGE CHARGE CHARGE VALVE VALVE VALVE VALVE H H H H2 2 2 2O O O O CHARGE CHARGE CHARGE CHARGE VALVE VALVE VALVE VALVE COLD COLD COLD COLD H H H H2 2 2 2O O O O VALVE VALVE ...

Page 18: ...onfigurable applications Configurable applications The controller firmware can manage up to nine different applications The desired application can be enabled using parameter e1 as per the following list 0 None 1 Electric hot plates 2 Bain marie 3 Tilting pans 4 Boiling pans 5 Fry Tops 6 Cast iron grills 7 Fryers 8 Pasta cookers 9 Ovens ...

Page 19: ...Outputs available Heater Information displayed The display shows the power value and the cooking time After switch on During regulation Available functions Device ON OFF When the display is switched on the default values are loaded Power 0 Time 00 00mm ss Power regulation Selection interval 0 6 Selection of cooking time Selection range 00 00 59 59 mm ss Refresh This reloads the last time value set...

Page 20: ...N 10 r28 OFF Regulator 6 12 r29 ON 10 r30 OFF Heating is interrupted when the power regulator is set with a value of 0 or when the controller is switched OFF At the end of the countdown when the time is 00 00 the buzzer will sound until the button on the push encoder or one of the six function keys is pressed or until the timeout interval set by the relative parameter e2 elapses with a cycle of 0 ...

Page 21: ...mperature can refer to the reading or the setpoint depending on how parameter e4 is set Below is an example of the display when timed cooking has been selected Switch on screen Regulation screen Available functions Device ON OFF When the display is switched on the following values are uploaded Type of cooking last cooking selected Temperature 0 Time 00 00 Selection of type of cooking Time regulati...

Page 22: ...lected Timed cooking T cooking Needle cooking The selection ranges intervals for each value are the following Temperature of regulation probe 0 300 C Temperature of T 0 150 C Time 00 00 24 00 hh mm Temperature of needle probe 0 r4 99 r5 C Selection of heaters Top heaters on Bottom heaters on Top bottom heaters on Refresh This reloads the last time value set on the selected timer ...

Page 23: ...re detected by the needle probe that is temperature detected by the needle probe Delta T setpoint When the set temperature is reached a warning icon will appear on the screen The icon will disappear only when the temperature setpoint is changed or the controller switched off Heating is interrupted when the controller is switched off When the needle temperature is reached or the countdown ends time...

Page 24: ...displayed Depending on the type of cooking selected the values that can be displayed are time power regulation probe temperature or needle probe temperature The temperature can refer to the reading or the setpoint depending on how parameter e4 is set Below is an example of the display when timed cooking has been selected Available functions Device ON OFF When the display is switched on the followi...

Page 25: ...point of the regulation probe and a signal based on the needle probe setpoint Power Time regulation is carried out taking into consideration the value of the regulation power and a signal based on a timer count Power Needle regulation is carried out taking into consideration the value of the regulation power and a signal based on the setpoint of the needle probe Setting the setpoint Only the setta...

Page 26: ...the solenoid valve will also be deactivated Heating The controller begins heating when the value of the regulation probe is lower than the set value heating will be interrupted when the value is higher Heating is restored in the same way when the value goes down again When the set temperature is reached a warning icon will appear on the screen The icon will disappear only when the temperature setp...

Page 27: ...ts is configured as technical room fans value set to 11 the fans are always on except for models with J K thermocouples where they are activated when the threshold set by parameter r37 is exceeded If one of the available outputs is configured as ON OFF value set to 14 the relay will operate as follows OFF when the device is on stand by mode ON under all other conditions ...

Page 28: ...unctions Device ON OFF When the display is switched on the following values are uploaded Power 0 Timer time 00 00 hh mm Power regulation Selection interval 0 9 Selection of cooking time Selection range 00 00 23 59 hh mm Hot water filling activation deactivation of the solenoid valve to fill the tank This key works in a similar way to a switch the solenoid valve is activated when it is pressed When...

Page 29: ... 0 based on the regulation value set by the relative parameters Regulator 1 3 ON r19 45 OFF r20 Regulator 2 4 ON r21 38 OFF r22 Regulator 3 5 ON r23 32 OFF r24 Regulator 4 7 ON r25 29 OFF r26 Regulator 5 9 ON r27 30 OFF r28 Regulator 6 13 ON r29 32 OFF r30 Regulator 7 21 ON r31 37 OFF r32 Regulator 8 45 ON r33 60 OFF r34 Regulator 9 always ON r35 r36 Heating is interrupted when the power regulator...

Page 30: ... time regulation probe temperature or needle probe temperature The temperature can refer to the reading or the setpoint depending on how parameter e4 is set Below is an example of the display when timed cooking has been selected Available functions Device ON OFF When the display is switched on the following values are uploaded Type of cooking the last selected Temperature of regulation probe and o...

Page 31: ... hours minutes or minutes seconds on the timer are modified separately If confirmation is not given within 5 seconds it will automatically validate the displayed value The unit begins heating when the value of the regulation probe is lower than the set value heating will be interrupted when the value is higher Heating is restored in the same way when the value goes down again When the set temperat...

Page 32: ...e of the available outputs is configured as ON OFF value set to 14 the relay will operate as follows OFF when the device is on stand by mode ON under all other conditions Management of the auxiliary relay If one of the available outputs is configured as AUX value set to 15 the label AUX will be displayed above the fourth function key otherwise it is not displayed The color is grey when the relay i...

Page 33: ...able Heater Technical room fans ON OFF Information displayed The display shows the power value and the cooking time After switch on During regulation Available functions Device ON OFF When the display is switched on the following values are uploaded Power 0 Time 00 00mm ss Power regulation Selection interval 0 9 Selection cooking time Selection range 00 00 59 59 mm ss Refresh This reloads the last...

Page 34: ... r30 Regulator 7 21 ON r31 37 OFF r32 Regulator 8 45 ON r33 60 OFF r34 Regulator 9 always ON r35 r36 Heating is interrupted when the power regulator is set with a value of 0 or when the controller is switched OFF When countdown ends time at 00 00 the buzzer will sound until the button on the push encoder or one of the 6 function keys is pressed or or until the timeout interval set by the relative ...

Page 35: ... T2 Available functions Device ON OFF When the display is switched on the following values are uploaded Temperature 0 Time T1 00 00 Selection of tank temperature Selection range 0 r1 200 C r2 Selection of active basket Choice of basket which the timer applies to If motor driven baskets are in use see paragraph Management of motor driven baskets Selection of cooking time referring to the selected b...

Page 36: ... r12 if the probe temperature 47 C r11 the heater is active if 47 C r11 probe temperature 60 C r12 the heater is activated for 10 r13 as soon as the temperature goes down 1 C r14 the previous point is repeated if the probe temperature 60 C r12 the heater is off regulation resumes as soon as the temperature goes below 2 C r16 compared to the setpoint When the set temperature is reached a warning ic...

Page 37: ... a time10 0 if e10 0 the key shall be touched again to go back to the initial status defined by e9 From encoder turn the push encoder until the desired timer function lights up hold it for 3 seconds Automatic operation e8 1 From key the corresponding relay will change status for the time selected with the cooking setting and go back to the initial status defined by e9 once the countdown ends From ...

Page 38: ...ket When the machine is switched on only the time T1 of the first basket will be displayed by default while the timers T2 to T6 will only be displayed when selected Once the timer has elapsed the display will still show the value 0 until the controller is switched off After switch on During regulation with more timers selected Available functions Device ON OFF When the display is switched on the f...

Page 39: ...the timer are modified separately If confirmation is not given within 5 seconds it will automatically validate the displayed value The controller begins regulation when the value of the energy regulator is anything other than 0 based on the regulation value set by the relative parameters Regulator 1 3 ON r19 45 OFF r20 Regulator 2 4 ON r21 38 OFF r22 Regulator 3 5 ON r23 32 OFF r24 Regulator 4 7 O...

Page 40: ...able functions Device ON OFF When the display is switched on the following values are uploaded Temperature 0 Timer time 00 00 hh mm Selection of tank temperature Selection range 0 r1 90 C r2 Selection of cooking time Selection range 00 00 59 59 mm ss Water filling activation deactivation of the solenoid valve to fill the tank This key works in a similar way to a switch the solenoid valve is activa...

Page 41: ...witched off Water filling if the controller goes from OFF to ON and the water level sensor is fitted the water load valve will be managed as follows initial activation is always carried out using the key keeping it held down and the valve will automatically be deactivated once the maximum level has been reached Once the maximum level has been reached if the water level goes below the minimum level...

Page 42: ...rm output will be activated Power failure alarm Power failure alarm Power failure alarm Power failure alarm check the device network connection when power is restored regulation must be reactivated manually the alarm output will be activated Door open alarm Door open alarm Door open alarm Door open alarm close the door the alarm output will be activated Boar Boar Boar Board temperature alarm only ...

Page 43: ...ged PW 20 all the parameters will be visible but cannot be changed Restore parameters PW 149 the default parameters of the active application will be restored N B when the operation is complete the controller will automatically return to the OFF position Changes using the keypad If the REFRESH key is held down for 3 seconds on the OFF screen access will be granted to the configuration screen Confi...

Page 44: ...ion Main regulation Main regulation r0 r0 r0 r0 Cabinet setpoint differential 1 30 C F NA 2 2 NA 2 NA 2 NA 2 r1 r1 r1 r1 Minimum cabinet setpoint 50 r2 C F NA 0 0 NA 0 NA 0 NA 0 r2 r2 r2 r2 Maximum cabinet setpoint r1 450 C F NA 90 300 NA 300 NA 200 NA 300 r3 r3 r3 r3 Cabinet setpoint 99 9 99 9 C F NA 0 0 NA 0 NA 0 NA 0 r4 r4 r4 r4 Minimum needle setpoint 50 r5 C F NA NA 0 NA 0 NA NA NA 0 r5 r5 r5...

Page 45: ...27 0 power regulator 5 is always on 0 240 Sec 10 NA 30 30 NA 30 NA 30 NA r29 r29 r29 r29 Time power regulator 6 is on 1 240 Sec 12 NA 13 13 NA 13 NA 13 NA r30 r30 r30 r30 Time power regulator 6 is off if r30 0 and r29 0 power regulator 6 is always on 0 240 Sec 10 NA 32 32 NA 32 NA 32 NA r31 r31 r31 r31 Time power regulator 7 is on 1 240 Sec NA NA 21 21 NA 21 NA 21 NA r32 r32 r32 r32 Time power reg...

Page 46: ...3 Maximum power 0 3 0 0 0 0 0 0 0 0 0 iP3 iP3 iP3 iP3 Multi purpose input 2 activation 0 With contact closed 1 With contact open 0 1 0 0 0 0 0 0 0 0 0 i7 i7 i7 i7 Delay in water loading stop 0 240 s NA 4 NA NA NA NA NA NA NA Alarms Alarms Alarms Alarms A0 A0 A0 A0 Display regulation probe alarm 0 No 1 Yes 0 1 NA 1 1 NA 1 NA 1 NA 1 A2 A2 A2 A2 Display needle probe alarm 0 No 1 Yes 0 1 NA NA 1 NA 1 ...

Page 47: ...c2 uc2 uc2 K2 relay configuration as uc1 0 15 0 4 4 5 15 0 12 7 3 uc4 uc4 uc4 uc4 K4 relay configuration as uc1 0 15 11 10 11 6 11 11 11 8 11 uc5 uc5 uc5 uc5 K5 relay configuration as uc1 0 15 14 14 14 14 14 14 14 14 14 uc6 uc6 uc6 uc6 K6 relay configuration as uc1 0 15 0 11 0 11 0 0 13 11 0 PSr PSr PSr PSr Enable silencing alarm output 0 No 1 Yes 0 1 1 1 1 1 1 1 1 1 1 Pbu Pbu Pbu Pbu Buzzer confi...

Page 48: ...NA NA 0 NA NA e8 e8 e8 e8 Basket operation mode 0 manual 1 automatic 0 1 ND ND ND ND ND ND 1 ND ND e9 e9 e9 e9 Relay status from Stand by to ON 0 deactivated 1 activated In stand by mode the relays are always deactivated 0 1 ND ND ND ND ND ND 0 ND ND e10 e10 e10 e10 Basket relay status change If e10 0 the relay status will be changed touching again for 3 seconds the corresponding timer key T1 o T2...

Page 49: ...al blocks for wires up to 2 5 mm plug in screw terminal blocks for wires up to 2 5 mm on request Pico Blade connector Maximum permitted length for connection cables power supply 10 m 32 8 ft analogue inputs 10 m 32 8 ft digital inputs 10 m 32 8 ft digital outputs 10 m 32 8 ft Operating temperature from 5 to 55 C from 23 to 131 F Storage temperature from 25 to 70 C from 13 to 158 F Operating humidi...

Page 50: ...50 VAC command for solid state relays 12 VDC 15 mA max K4 relay electro mechanical relay SPST 8 A res 250 VAC electro mechanical relay SPST 8 A res 250 VAC electro mechanical relay SPST 8 A res 250 VAC K5 relay electro mechanical relay SPST 5 A res 250 VAC electro mechanical relay SPST 8 A res 250 VAC electro mechanical relay SPST 8 A res 250 VAC K6 relay electro mechanical relay SPST 5 A res 250 ...

Page 51: ...EVJ 700 EVJ 700 EVJ 700 EVJ 700 Application Manual 144EVJ700E104 EVCO 29 10 2019 ...

Page 52: ... thus protected by the Italian Intellectual Property Rights Code CPI EVCO imposes an absolute ban on the full or partial reproduction and disclosure of the content other than with the express approval of EVCO The customer manufacturer installer or end user assumes all responsibility for the configuration of the device EVCO accepts no liability for any possible errors in this document and reserves ...

Reviews: