EVJ 700
EVJ 700
EVJ 700
EVJ 700 ----
Application Manual:
144EVJ700E204
EVCO | 29.01.2021
| 31
Setting the setpoint
Only the settable values are displayed, according to the type of cooking selected.
Timed cooking
Needle cooking
The selection ranges/intervals for each value are the following:
Temperature of regulation probe [0 <-> 300°C]
Time [00:00 <-> 59:59 mm:ss]
Temperature of needle probe [0 (r4) <-> 99 (r5) °C]
Auxiliary relay
It makes it possible to manually modify the relay status (see paragraph “Management of the auxiliary relay”)
Refresh
This reloads the last time value set on the selected timer
Operation
–
All the functions listed above can be selected using the function keys or the push encoder, as described in the general
introduction.
–
During setting, the value to change will flash.
The hours/minutes or minutes/seconds on the timer are modified separately.
If confirmation is not given within 5 seconds, it will automatically validate the displayed value.
–
The unit begins heating when the value of the regulation probe is lower than the set value; heating will be interrupted
when the value is higher. Heating is restored in the same way, when the value goes down again.
–
When the set temperature is reached, a warning icon
will appear on the screen.
The icon will disappear only when the temperature setpoint is changed or the controller switched
off.
–
The device will interrupt heating when switched OFF.
–
When the needle temperature is reached or the countdown ends (time at 00:00), the buzzer will sound until the button
on the push encoder (or one of the 6 function keys) is pressed or until the timeout interval set by the relative parameter
(e2) elapses, with a cycle of 0.5 “ON/0.5” OFF. This does not affect the regulation, the device will continue normal
regulation.