04. MINIMUM INSTALLATION REQUIREMENTS 

 

INTRODUCTION: 

 

INSTALLATION WITH WALL FUME OUTLET IS PROHIBITED. INSTEAD THE FUME OUTLET MUST BE ROOF-TYPE AS PROVIDED FOR BY NATIONAL 

REGULATIONS. 

 

Eva Stampaggi S.r.l. assumes no responsibility for injury to persons and/or damage to property caused by the non-observance of the point 

highlighted above for non-compliant installed products. 

Install the stove according to the regulations in force in the country of use. 

 

In Italy, for example, this refers to UNI 10683: 2012, which refers to 4 areas: 

 

a. preliminary activities -

 are under the jurisdiction and are the responsibility of the reseller/installer at the time of the pre-installation inspection. Preliminary 

procedures include: 

  installation site suitability verification; 

  fume evacuation system suitability verification; 

  external air inlet suitability verification. 

At this stage, the product needs to be checked in order that it can be safely operated and that the relevant technical specifications are met. 

Safety conditions must be assessed with a preventive inspection. 

Stoves and fireplaces are heating systems and must be installed safely

 

and comply with the manufacturer's instructions!

 

 

b. installation -

 under the responsibility of the installer. In this phase the 

installation 

of the product and the smoke exhaustion system are considered as well as 

the handling of topics such as: 

 

safety distance

 from combustible materials; 

 

chimney flue construction

, smoke ducts, intubated systems and chimney cowls. 

 

c. issuance of supplementary documentation

 - the responsibility of the installer. 

The release of technical documentation must include: 

  manual of use and maintenance of the appliance and of the components of the system (e.g. smoke ducts, chimney flue, etc.); 

  Photocopy or photograph of the chimney flue plate; 

  system manual: (if applicable); 

 

Declaration of Conformity in relation to Ministerial Decree 37/08

 

d. control and maintenance

 - the responsibility of the maintenance technician who must oversee protection and maintenance of the product during its operation 

over time.

 

The operator responsible for checking and maintaining the systems for winter and summer climate control carries out tasks in 

a workmanlike manner

 

and in observance of applicable regulations. The operator, at the end of these operations, must draw up and sign a technical inspection report in accordance with 

the models provided by the provisions of this decree and the implementing rules, in relation to the type and capacity of the system, to be issued to the person who 

signs a copy thereby confirming receipt and reading thereof.

 

 

In addition to what is specifically provided for in the following paragraphs of this Instruction Manual, the Purchaser must comply with the following minimum 

installation requirements: 

a)  Do not invert or place the stove horizontally on one side; 

b)  The heat output of the stove must be adapted to the size of the room where it is to be installed and the room must be ventilated from the outside; 

c)  The assembly of the flue pipe must be carried out in a workmanlike manner and according to European (UNI 10683) and national regulations, local 

regulations and the technical specifications and warnings contained in this Instruction Manual; 

d)  The smoke outlet must be connected to the flue pipe by means of telescopic fittings; 

e)  The diameter of the flue must be less than 150 mm. 

f)  The connection to the flue pipe must be made with an inclination connection of less than 45°; 

g)  The flue pipe must be suitably insulated; 

h)  The minimum length of the horizontal section must be greater than 2 metres; 

i) 

The minimum slope of the horizontal section must be 5%; 

j) 

The chimney and/or flue pipe must be waterproofed; 

k)  The flue shall not have more than two changes of direction; 

l) 

The flue gas must be discharged directly into the flue pipe; 

m)  The flue gas duct must have a length of less than 6.0 m before the flue, with a maximum horizontal section of 3.0 m; 

n)  The flue and flue duct must not narrow in width from the initial diameter for its entire length. The initial diameter shall be that of the exhaust outlet of the 

stove body; 

o)  The minimum ventilation duct opening must be 80 cm²; 

p)  The distance of the flammable walls must be respected, as prescribed on the “stove data plate”; 

q)  The burn pot must be cleaned before each ignition of the stove. 

The Buyer must not make any structural changes to the stove and must not make any operating changes to the electrical board. 

Installation and connection must be carried out by the Purchaser and by qualified technical personnel, in compliance with European (UNI 10683) and national 

regulations, local regulations and assembly instructions contained in this Instruction Manual. 

Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect, for damage to persons or property resulting from non-compliance with the 

aforementioned provisions of law, assembly instructions, warnings and general safety rules indicated in this Instruction Manual. 

Failure to comply with the installation requirements and/or tampering with the stove may result in: inadequate heat output and/or abnormal product behaviour, 

poor flue gas draught, clogging of the burn pot, slow combustion, hopper fire, overheating and fire hazard of the stove, fire hazard of the flue gas duct, or lack of 

oxygen in the environment where the stove is located. 

Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused 

by non-compliance with the requirements for installation of the stove and/or tampering with it. 

The Buyer must request and retain the certification of compliance of the installation, and the connection of the stove, with the provisions of law. In the absence of 

such certification Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage caused to 

persons or property, resulting from the use of the product. 

 

Caution: in the event of ignition fault or power outage, the burn pot must be emptied before repeating the operation. Failure to follow this procedure 

may result in glass breakage. 

 

 

 

 

 

 

 

 

 

 

6

Summary of Contents for SB 80

Page 1: ...INSTRUCTION MANUAL PELLET STORAGE WATER HEATER PELLET THERMO STOVE Models SB 80 TEK 80 EN...

Page 2: ...o facilitate stove s ignition 6 Should any anomaly concerning the flame be detected or however in any other case NEVER SWITCH OFF the stove by disconnecting it from the mains Use the relevant button D...

Page 3: ...INSTALLATION WARNINGS p 9 06 01 CONNECTION SYSTEM SCHEMATICS p 11 07 INSTALLATION p 12 07 01 HYDRAULIC CONNECTION p 13 07 02 ELECTRICAL CONNECTION p 15 08 ELECTRONICS WITH N 100 3 BUTTON LED DISPLAY p...

Page 4: ...s type Y the power supply cable may only be replaced by a qualified technician Should the power supply cable be damaged it can be replaced only by the manufacturer or by its technical assistance servi...

Page 5: ...appliance will be automatically switched off It may take two separate ignitions to resume operation at ideal working conditions since the Auger tube is very long CAUTION If the stove is not properly i...

Page 6: ...ket Temperatura uscita fumi C 230 136 Flue gas mass flow Flusso massico dei fumi g s 5 7 3 2 Efficiency Rendimento 90 0 93 5 Total heat output Potenza termica Kw 10 2 5 0 Water heat output Potenza ter...

Page 7: ...mbly of the flue pipe must be carried out in a workmanlike manner and according to European UNI 10683 and national regulations local regulations and the technical specifications and warnings contained...

Page 8: ...ould the existing flue opening not be perfectly perpendicular to the firebox fume outlet use an elbow to connect them The angle with respect to the vertical must never exceed 45 see figure to the side...

Page 9: ...o an excess of oxygen wears the combustion chamber prematurely A poor draught however slows combustion resulting in a decrease in the stove temperature fume egress inside rooms a loss of stove efficie...

Page 10: ...ges storage rooms for combustible materials etc These air intakes must be created in such a way that they cannot be obstructed either internally or externally and must be protected by a grille wire me...

Page 11: ...RECT INSTALLATION Exhaust pipes must never be fitted pointing downwards or horizontally so that fumes are discharged directly through the external wall Outdoor air intake with non resealable grid Outd...

Page 12: ...06 1 CONNECTION SYSTEM SCHEMATICS STORAGE WATER HEATER MODE THERMO STOVE MODE 11...

Page 13: ...itable guards provided that they do not reduce the minimum cross section When in operation the pellet stove may cause a negative pressure in the room where it is installed No other naked flame applian...

Page 14: ...40 85 0 03590 90 0 03960 100 0 04340 110 0 05150 Safety hydraulic circuit according to EN 1487 2014 or equivalent in force STORAGE HEATER INSTALLATION MODE ONLY Safety units are devices used in sanita...

Page 15: ...talled The manufacturer assume no liability for damage to property or injury to persons following failure to install the safety devices correctly THERMO STOVE MODE INSTALLATION Remove the 2 covers for...

Page 16: ...er on the rear of the item EXTERNAL THERMOSTAT If the item is chosen as a thermo stove an external thermostat may still be installed This operation may only be performed by authorised personnel Use a...

Page 17: ...can be enabled or disabled Moreover if the time is set to OFF the clock ignores the corresponding control Caution set carefully to prevent overlapping of different activation times of different progra...

Page 18: ...the exhaust blower switch on Any problem detected during the switching on phase is indicated on the display and the stove goes into alarm status Pellet loading After approx 1 minute the pellet loading...

Page 19: ...ire alarm phase Should the alarm not be cleared the stove will in any case be switched off and the alarm message will remain on the display AL1 BLAC OUT Power outage alarm Power outage may occur with...

Page 20: ...displayed and the system is shut down Unscrew the black cap near the pellet hopper cover and press the button to reset the contact SERVICE MESSAGE The stove will display the message SERVICE or SER du...

Page 21: ...lid Caution Only use a dry cloth to clean the stove Do not use abrasive material or products that could corrode or bleach surfaces At the end of the season with the last ignition the pellet remaining...

Page 22: ...MODE BURN POT CLEANING WARNING APPEARS AFTER 8 HOURS OF STOVE OPERATION 4 5 KW MODELS ONLY 8 HOURS ARE CUMULATIVE TO CLEAR THE WARNING PRESS ALL 3 BUTTONS ON THE DISPLAY FOR 4 5 SECONDS IRREGULAR SLOW...

Page 23: ...ED CORRECTLY CALL TECHNICAL SUPPORT THERM DOOR SAFETY ALARM THERMAL SAFETY THERMOSTAT OR FIRE DOOR OPEN CLOSED INCORRECTLY LET THE STOVE COOL RE ARM THE MANUAL THERMOSTAT AT THE REAR RESTART THE STOVE...

Page 24: ...tenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ____________ Tech...

Page 25: ...needed to correctly use operate and perform maintenance on the appliance CUSTOMER Signature DEALER INSTALLER Signature CERTIFICATE OF INSTALLATION AND TESTING CUSTOMER _______________________________...

Page 26: ...istics of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness any small cracks or cracks that could be hi...

Page 27: ...sponsibility for such disposal is to be borne by the owner and to not incur sanctions or adverse effects on the environment and health we recommend you contact the local administration the local waste...

Page 28: ...tion totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vor...

Reviews: