07.2 ELECTRICAL CONNECTION
The electrical connection must be performed by qualified personnel who install circuit
breakers upstream of the appliance. Particular attention must be paid when the stove
is an integration to the system and all the equipment must operate as planned.
Avoid installations with electric cables that run close to fume pipes or hot components
that are suitably insulated.
The voltage is 230V while the frequency is 50 Hz.
The electrical system, at the connection point, must include an earth connection as
required by EEC Regulation 73/23 and EEC 93/98.
THERMO-STOVE MODE ONLY
Remove the cover on the rear of the item.
EXTERNAL THERMOSTAT.
If the item is chosen as a thermo-stove, an external thermostat may still be
installed. This operation may only be performed by authorised personnel. Use a 2-
pole cable with everyday double insulation. In the event that the thermostat is
closed, the stove functions at the set heat output. If the thermostat opened, the
stove would work in MODULATE mode until the thermostat closes.
The poles of the thermostat are to be found on the right, above the wording T.EXT.
PUMP.
The pump must be connected under the wording PUMP and Phase, Neutral and
PE must also be connected.
IMPORTANT:
There are 3 modes of operation depending on the installation of the item. These 3 modes can be set by technical parameters that only the installer may access.
The 3 ways are described below.
15