11 Product installation and power supply
BoltGATE 20-31 User's manual EN
11.5.6
How to turn OFF the system
There are two ways to turn OFF the system:
l
By executing the
poweroff
Linux command
l
By turning OFF the Ignition Key
To turn OFF the system by executing the
poweroff
command, complete the following steps:
1. Login the Administration Console
2. Execute the
poweroff
command. The system turns OFF (only if the ignition key is OFF
otherwise it reboots.) To turn OFF the CPU while the ignition key is on, execute this command
first:
echo 0 >/sys/class/hwmon/hwmonX/cpu_sleep_action
3. Remove the power from the Power IN connector.
To turn OFF the system by turning OFF the Ignition Key, complete the following steps:
1. Turn OFF the Ignition Key. The system turns OFF after 120 seconds (default condition).
If you want to change the 120 seconds timeout execute this command:
echo xx >>/sys/class/hwmon/hwmonX/ignition_key_timeout
xx is the new value in seconds. [0….19999999]
2. Remove the power from the Power IN connector.
11.5.7
How to trigger a hardware reset of the system
To trigger a hardware reset of the system, push the reset pushbutton.
90 / 98
© 2022 Eurotech SpA - Via Fratelli Solari 3/A - 33020 AMARO (UD) - Italy
Code: BTGATE-20-31_MAN_EN_1-6
Revision: 1-6 2022.07.28
Summary of Contents for BoltGATE 20-31
Page 4: ...This page is intentionally left blank...
Page 8: ...This page is intentionally left blank...
Page 12: ...This page is intentionally left blank...
Page 16: ...This page is intentionally left blank...
Page 80: ...This page is intentionally left blank...
Page 97: ...BoltGATE 20 31 User manual Rev 1 4 Notes NOTES Id BTGATE 20 31_Man_ENG_1 4 97 98...