6.10 MAINTENANCE TO BE PERFORMED BY AN AUTHORISED TECHNICIAN
Task
Frequency*
General professional inspection
and servicing of the stove (& the
flue)
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Clean/sweep the flue gas system
Twice a season; the first time at the start of
the season
Replacement of parts that are not
mentioned in this manual
When damage is identified
Check the connection between the
stove and chimney/the flue
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
All other service work not specifi-
cally mentioned in this manual.
Once a season at the start of the season
Clean the room blower/flue blow-
er
Twice a season; the first time at the start
of the season and/or after 900 combustion
hours, when the stove displays SERV
Cleaning the stove inside and out
Once a season or after 900 combustion
hours when the stove displays SERV
Lubricate the pellet auger gear
unit
Once a season at the end of the season
Clean the smoke chamber
Once a season; at the end of the season or
after 900 combustion hours when the stove
displays SERV
Check the ignition element
Once a season
Clean the air side of the heat ex-
changer
Once a season or after 900 combustion
hours when the stove displays SERV
Clean the flue side of the heat ex-
changer
Once a season or after 900 combustion
hours when the stove displays SERV
Check the electrical parts such as
the PCB, the wiring, the sensors
and safety devices.
Once a season or after 900 combustion
hours when the stove displays SERV
Check the silicon hoses on the pres-
sure sensor
Once a season or after 900 combustion
hours when the stove displays SERV
Check the door seal and replace if
necessary.
Twice a season; the first time at the start of
the season or after 900 combustion hours
when the stove displays SERV
Test the stove at all 5 combustion
levels
Once a season or after 900 combustion
hours when the stove displays SERV
Test the safety devices
Once a season or after 900 combustion
hours when the stove displays SERV
(*) The specified frequency is a minimum. Local law and/or your insurance contract
may prevail depending on which is stricter. If the stove is used intensively, the flue
must be cleaned more frequently.
7. TECHNICAL SERVICE, ORIGINAL SPARE PARTS
Before any stove leaves the factory, it is first thoroughly tested and started up. Any
repairs or commissioning work that proves necessary during or after installation
4
Summary of Contents for Eurostove 74 S-Line
Page 37: ...37 2...
Page 69: ...69 6...
Page 134: ...134 3 SEULEMENT POUR LA BELGIQUE Eurostove 74 S line Eurostove...
Page 135: ...135 3 SEULEMENT POUR LA BELGIQUE...
Page 167: ...167 4...
Page 232: ...232 1 ENKEL VAN TOEPASSING VOOR BELGI Eurostove 74 S line Eurostove...
Page 233: ...233 1 ENKEL VAN TOEPASSING VOOR BELGI...
Page 269: ...269 9...
Page 301: ...301...
Page 328: ...328 y 10 GARANCIJSKI POGOJI...
Page 330: ...330...
Page 331: ...331 1 16 17...
Page 332: ...332 18 19 20...
Page 333: ...333 21 22 23...
Page 334: ...334 24 25 26...
Page 335: ...335 27 28 29...
Page 336: ...336 30 31 32...
Page 337: ...337 33 34 35...
Page 338: ...338 36 37 38...
Page 339: ...339 39...