6.10.
FLOOR SENSOR CONNECTION
a.
Check if J1 jumper is in the floor position (point 4.4.)
b.
Connect the floor sensor to terminals No. 4 and 5 in the thermostat.
c.
Reset the thermostat.
d.
The thermostat operates according to floor sensor indications. The range of controlled
temperature increases to 45°C.
The standard temperature sensor is inactive.
7.
RX RECEIVER SETTINGS
7.1.
Establishing a connection between 2006TX thermostat with RX receiver or
receivers (pairing)
Each thermostat and each receiver has a unique number distinguishing it from other
thermostats. It is not possible for any thermostat not paired with the particular receiver to
interfere with the operation of another pair or set.
The thermostat may be paired with other receivers at any time. Neither a blackout, battery
replacement nor a complete reset of all thermostat settings affects the pairing of devices in
any way.
Pairing procedure:
•
RESET button (under the front cover),
•
remove the thermostat housing,
•
press the button on the transmitter plate three times
–
the signaling LED starts flashing
alternately in red and green,
•
insert the RX receiver to the power socket,
•
press the receiver button 3 times
–
blue signaling LED lights up,
•
when the connection is established the blue LED switches off,
•
if one receiver only is used, press the transmitter button, the LED switches off. Pairing
mode is completed.
If several (maximum 6) receivers are to be paired:
•
After detection of the first receiver,
•
Insert the second receiver to the power socket
•
Press the receiver button 3 times
–
blue signaling LED lights up
•
After detection of the first receiver, the blue LED switches off
•
Follow the same steps to connect the subsequent receivers, then press the transmitter
button. Pairing mode is completed.
Note!
Pairing mode is only available for 10 minutes after connecting the receiver to the
mains,
restoring factory settings and inserting batteries into the thermostat!
Factory-established thermostat
–
receiver pairs are paired; however, pairing may be
repeated if necessary.
7.2.
Selection of operating mode
While keeping the button
“B”
pressed insert the receiver into the power socket. Depending on
the preset mode green or red LED lights up. Each pressing of the button changes the operating
mode. After a mode is selected, the receiver restores operation.