5.3.
Opening the thermostat
Use a cross-head screwdriver to loosen the housing locking screw. Separate the panel and
the base minding the hinges on the left side of the thermostat.
5.4.
Selecting thermostat operating mode
J4
–
the selection of heating
or cooling operating mode
Jumper position
J4
COOLING
COOL
J4
HEATING
HEAT
J1
–
the selection of sensor:
floor or room sensor.
This function is active only if
the J4 jumper is in the heating
position.
Jumper position
J1
FLOOR
The thermostat is con-
trolled by the floor sensor.
J1
ROOM
The thermostat is con-
trolled by the room sensor.
5.5.
Insertion and replacement of batteries
Place the batteries in the thermostat while observing the correct polarity. There are installation
markings in the battery compartment. Then install (snap) the thermostat onto the base.
The battery indicator will be visible when the battery voltage reaches the minimum allowable
level. It is recommended to replace the batteries with new alkaline batteries before each heat-
ing season. Reprogram the controller if necessary.
CAUTION! Use only alkaline AA batteries to power the thermostat. Do not use
rechargeable batteries because their voltage is lower, and their effective time is
shorter.
6.
THERMOSTAT SETTINGS
6.1.
SETTING THE CLOCK
a.
Set the knob in the START position.
b.
To set the clock press
.
c.
Use or buttons to select a weekday.
d.
To set the hour push
button again.
e.
Use or buttons to set correct time.
f.
Repeat the
and
/
sequence to set minutes.
g.
After five seconds the setting is stored, and the device restores operation.