background image

EUROSTER 2006TXRX 

 INSTALLATION AND OPERATION MANUAL

 

6

 

 

6.6.

 

RESTORING FACTORY SETTINGS 

a.

 

Press simultaneously HOLD and   buttons and while holding them press RESET. 

b.

 

Release all buttons. 

c.

 

Press the HOLD button twice and press RESET again. 

Factory settings

 

Default temperatures: 
Heating mode 

 

20.4°C 

 

16.2°C

 

Air-conditioning mode 

 

22.0°C 

 

25°C

 

Default time ranges:  
Monday 

 Friday 

 6.00 a.m. to 10.00 p.m. 

 10.00 p.m. to 6.00 a.m. 

Saturday 

 Sunday 

 6.30 a.m. to 10.30 p.m. 

 10.30 p.m. to 6:30 a.m. 

 

 

6.7.

 

SWITCHING OFF THE PROGRAM (operation with constant setting) / HOLD 

a.

 

Set the knob in the START position. 

b.

 

To  switch  off  the  program  and  set  the  constant  operating  temperature  press  HOLD. 

“Temp Set” (temperature setting) and “Hold” (program switched off) will be displayed.

 

c.

 

Use   and   buttons to set the desired temperature. 

d.

 

The display will flash for approx. 8 sec. upon the selection  of the desired temperature 
and then it will show the current room temperature. The thermostat starts operating in 
the  constant  setting  mode.  From  this  moment,  the  thermostat  maintains  a  constant 
temperature, set by the user, regardless of the programs. 

e.

 

To restore operation according to the program, press HOLD. 

6.8.

 

°C FROST PROTECTION SETTING

 

a.

 

Set the knob in the START position. 

b.

 

Press HOLD and hold it for 5 sec. 

A-

F”

 letters appear on the display. 

c.

 

Frost protection function is activated. Regardless of the moment of switching it on, the 
function is active until Monday 0.00 a.m. 

d.

 

To  switch  off  the  frost  protection  function  and  restore  operation  according  to  the  pro-
gram press HOLD again. 

6.9.

 

TEMPORARY (MANUAL) TEMPERATURE CHANGE 

Permits  a  temporary  change  of  temperature  without  modifying  the  stored  programs.  At  the 
nearest change of the comfort to economical temperature or in reverse, the thermostat auto-
matically restores operation according to the stored program. 

a.

 

Set the knob in the START position. 

b.

 

Press   or   button, to  show the  readout of the  current 

 or 

 temperature set-

ting. 

c.

 

Use   and   buttons to set the desired temperature. 

d.

 

After the selection of the desired temperature, the display will flash for approx. 8 sec. 
afterward  the  main  screen  will  be  displayed.  The  thermostat  starts  the  operation  ac-
cording to the temporary temperature change. During the operation according to tem-
porary  temperature  change  in  a  given  time  range  the 

 or   

 symbols  will  disap-

pear from the main display screen; MANUAL inscription will appear instead.  

e.

 

To restore the operation according to the program, turn the knob in either way and re-
turn it to the START position. 

 

 

Summary of Contents for 2006TXRX

Page 1: ...ture and economical night temperature Each temperature may be modified within the range of 5 35 C The thermostat is programmable in seven day cycles with an accuracy of 0 5 hour therefore it enables 4...

Page 2: ...when programming a thermostat 7 8 Multi purpose setting buttons increase decrease DISPLAY 9 Temporary change of temperature MANUAL sign is displayed to indicate that the temperature has been changed m...

Page 3: ...r liquids Do not install any units showing signs of mechanical damage The thermostat is not a safety component Additional protection devices must be used in systems prone to the risk of damage due to...

Page 4: ...the thermostat while observing the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base The battery indicator will be visible whe...

Page 5: ...C or 1 C d After five seconds the setting is stored and the device restores operation 6 4 TEMPERATURE READOUT CORRECTION a Set the knob in the MON position b Simultaneously press and hold for 3 sec H...

Page 6: ...HOLD 6 8 5 C FROST PROTECTION SETTING a Set the knob in the START position b Press HOLD and hold it for 5 sec A F letters appear on the display c Frost protection function is activated Regardless of...

Page 7: ...imes the signaling LED starts flashing alternately in red and green insert the RX receiver to the power socket press the receiver button 3 times blue signaling LED lights up when the connection is est...

Page 8: ...ication If the communication between the thermostat and the receiver is interrupted e g discharged batteries and such status lasts for 2 minutes no response from the receiver then the receiver switche...

Page 9: ...a soft cloth 11 DIMENSIONS 12 TECHNICAL DATA Controlled device heating air conditioning systems Supply voltage 3 V 2 pieces of alkaline AA batteries receiver 230 V 50 Hz Thermostat output relay volta...

Page 10: ...d out wheelie bin symbol Fig 1 The batteries are subject to selective collection in accordance with the provisions of the Directive 2006 66 EC of the European Parliament and of the Council Such markin...

Page 11: ...ce 4 The device may be repaired exclusively by the manufacturer or by a party clearly authorized by the manufacturer 5 Warranty becomes void in case of any mechanical damage incorrect operation and re...