Weight 

thermostat weight without batteries 

 115 g 

receiver 

 170 g 

Warranty period 

2 years 

Length of the receiver output cable 

2 m 

Frequency of set operation 

868 MHz 

Maximum power of transmission of the 
thermostat and the receiver 

< 25 mW 

Thermostat class: 

I  

Thermostat contribution to the seasonal 
energy efficiency of room heating  

 
1% 

13.

 

KIT CONTENTS 

 

Euroster 2006TX,

 thermostat 

 

Euroster RX,

 receiver 

 

2 pieces of alkaline AA batteries 

 

thermostat stand 

 

Installation and Operation Manual with Warranty Certificate 

14.

 

SIMPLIFIED DECLARATION OF CONFORMITY 

P.H.P.U.  AS  AGNIESZKA  SZYMAŃSKA

-

KACZYŃSKA  hereby  represents  that  the  type  of 

EUROSTER  2006TXRX  equipment  conforms  to  the  following  directives:  2014/35/EU  (LVD), 
2014/30/EU (EMC), 2014/53/EU (RED), 2011/65/EU (RoHS). 
The complete text of the Declaration of EU conformity is available at the following Internet 
address:  

www.euroster.pl 

15.

 

ELECTRONIC WASTE MANAGEMENT INFORMATION 

This  product  is  designed  and  manufactured  from  high-quality  materials  and 
components suitable for reuse.  
The  crossed-out  wheelie  bin  symbol  located  on  the  product  (Fig. 1)  means  that 
the product is subject to selective collection under the provisions of the Directive 
2012/19/EU of the European Parliament and of the Council.  
The product contains batteries, which are marked with a crossed-out wheelie bin 

symbol  (Fig. 1).  The  batteries  are  subject  to  selective  collection  in  accordance  with  the 
provisions of the Directive 2006/66/EC of the European Parliament and of the Council. 
Such  marking  informs  that  the  electrical  and  electronic  equipment  as  well  as  batteries  and 
accumulators may not be disposed of together with other household waste after their service 
life has ended. The user is obliged to take the used devices and batteries or accumulators to  
a  point  of  collection  of  waste  electrical  and  electronic  equipment  and  batteries  and 
accumulators.  The  entities  collecting  such  equipment,  including  the  local  collection  points, 
shops,  and  municipal  entities,  set  up  an  appropriate  system  enabling  handover  of  such 
equipment and batteries and accumulators. The proper disposal of waste equipment, batteries 
and  accumulators  contributes  to  the  prevention  of  consequences  hazardous  to  the  health  of 
persons  and  nature,  resulting  from  the  possible  presence  of  hazardous  components  in  the 
equipment  and  batteries  and  from  inaccurate  storage  and  processing  of  such  equipment  and 
batteries. 
Households  play  an  important  role  in  contributing  to  reuse  and  recovery,  including  recycling,  
of  waste  equipment. The attitudes influencing  the protection  of the common good  of  a  clean 
environment  are  shaped  at  this  level.  Households  are  also  one  of  the  larger  users  of  small 
equipment  and  its  rational  management  at  this  level  impacts  the  recovery  of  recyclables. 
Inaccurate disposal of this product may be penalized in accordance with national legislation.

 

 

 

Summary of Contents for 2006TXRX

Page 1: ...ture and economical night temperature Each temperature may be modified within the range of 5 35 C The thermostat is programmable in seven day cycles with an accuracy of 0 5 hour therefore it enables 4...

Page 2: ...when programming a thermostat 7 8 Multi purpose setting buttons increase decrease DISPLAY 9 Temporary change of temperature MANUAL sign is displayed to indicate that the temperature has been changed m...

Page 3: ...r liquids Do not install any units showing signs of mechanical damage The thermostat is not a safety component Additional protection devices must be used in systems prone to the risk of damage due to...

Page 4: ...the thermostat while observing the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base The battery indicator will be visible whe...

Page 5: ...C or 1 C d After five seconds the setting is stored and the device restores operation 6 4 TEMPERATURE READOUT CORRECTION a Set the knob in the MON position b Simultaneously press and hold for 3 sec H...

Page 6: ...HOLD 6 8 5 C FROST PROTECTION SETTING a Set the knob in the START position b Press HOLD and hold it for 5 sec A F letters appear on the display c Frost protection function is activated Regardless of...

Page 7: ...imes the signaling LED starts flashing alternately in red and green insert the RX receiver to the power socket press the receiver button 3 times blue signaling LED lights up when the connection is est...

Page 8: ...ication If the communication between the thermostat and the receiver is interrupted e g discharged batteries and such status lasts for 2 minutes no response from the receiver then the receiver switche...

Page 9: ...a soft cloth 11 DIMENSIONS 12 TECHNICAL DATA Controlled device heating air conditioning systems Supply voltage 3 V 2 pieces of alkaline AA batteries receiver 230 V 50 Hz Thermostat output relay volta...

Page 10: ...d out wheelie bin symbol Fig 1 The batteries are subject to selective collection in accordance with the provisions of the Directive 2006 66 EC of the European Parliament and of the Council Such markin...

Page 11: ...ce 4 The device may be repaired exclusively by the manufacturer or by a party clearly authorized by the manufacturer 5 Warranty becomes void in case of any mechanical damage incorrect operation and re...

Reviews: