EUROSTER 11WB User Manual Download Page 9

EUROSTER 11WB 

 USER MANUAL 

 

9

 

 

Any alarm generated while the ANTI-STOP function is active (overheating or sensor damage) 
aborts the function operation. 

17.

 

TROUBLESHOOTING 

Device does not work 

Burnt fuse or ROM failure 

 send the device to the service. 

The display blinks along with the sensor icon, "Sh" or "OP" letters appear 

Sensor  circuit  shorted  (

Sh

)  or  opened  (

OP

  check  the  adequate  sensor  cable  with  the 

blinking icon or send the device along with the sensors to the service. 

Pump or blower does not work 

The device is turned off 

 make sure that the proper icons are displayed. If not 

  check the 

settings. Restore factory settings (section 8). 
Wrong connection 

 check. 

Thermal protection activation 

 wait for the temperature decrease. 

Blower operates continuously 

Time interval between blow-throughs (setting No. 6) set at 0 

 adjust the value. 

Boiler is overheating 

The blow-through time setting (5) is too long or the time interval between blow-throughs is too 
short (setting No. 6) 

 adjust the value. 

The blower power too high 

 adjust the preset values of the power of the blower (3) and (4); 

throttle back the blower. 

Controller emits a buzzing sound 

Loose coils in the interference filter 

 does not impact the correct operation of the device. 

Controller knob operates erratically 

Pulse generator damage 

 send the device to the service. 

18.

 

STANDARDS AND CERTIFICATES 

EUROSTER 11WB

controller conforms to the following EU Directives: EMC, LVD and RoHS. 

The EC Declaration of Conformity is published and available at:

 

http://www.euroster.com.pl

 

19.

 

TECHNICAL DATA

 

Controlled device 

CH pump, blower, DHW pump

 

Supply voltage 

230 V 50 Hz

 

Maximum pumps output load 

2 A 230 V 50 Hz

 

Maximum blower output load 

0.5 A 230 V 50 Hz

 

Maximum power consumption 

1.6 W

 

Temperature measurement range 

from -5 

°C to +110

 

°C

 

Temperature adjustment range 

CH mode: from +20 

°C to +80

 

°C

 

DHW mode: from +20 

°C to +70

 

°C

 

Boiler temperature adjustment range 

from +40 

°C to +80

 

°C

 

Temperature adjustment accuracy 

°C

 

Hysteresis range 

from 2 

°C to 10

 

°C

 

Visual signalization 

backlit LCD

 

Operation temperature 

from +5 

°C to +40

 

°C 

 

Storage temperature 

from 0 

°C to +65

 

°C

 

Ingress protection rating 

IP40

 

Color 

black

 

Mounting method 

wall-mounted, screw anchors

 

Weight of the controller with cables 

0.86 kg

 

Length of cables 

controller power cable: 1.5 m 
CH pump power cable: 1.5 m 
DHW pump power cable: 1.5 m 
blower power cable: 1.5 m 
thermal protection cable: 1.5 m 

Summary of Contents for 11WB

Page 1: ...he operation of the CH and DHW circulation pumps EUROSTER 11WB controller is equipped with an Anti Stop function that prevents seizing of an idle pump rotor It automatically turns the pumps on for 30...

Page 2: ...point specially designed for that purpose or on an unshielded outlet pipe of the CH boiler as close to the boiler as possible fix the DHW sensor on the tank point specially designed for that purpose...

Page 3: ...t while the temperature is manually adjusted 4 Alarm icon blinks in case of alarm 5 Furnace status display see the description below 6 Blower icon lit at the time of blower operation 7 DHW pump icon l...

Page 4: ...g 1 restores factory settings bl Backlight will be displayed and once the knob is released 0 will appear Use the knob to select the required number 0 or 1 and confirm Selecting 0 results in automatic...

Page 5: ...sing between the end of the blow through cycle and the start of a new cycle It should be set so that to prevent the boiler temperature rise but on the other hand to avoid explosive combustion of the g...

Page 6: ...ump calculated by the controller 0 or 1 Press the knob to activate testing of the output Press the knob again or leave it inactive for 10 seconds to resume automatic operation 18 CH pump operation tes...

Page 7: ...tically resume the normal operation mode i e the pumps will not be turned off 11 FUELING Turn the blower off for the time the furnace is loaded with new fuel For this purpose turn the knob all the way...

Page 8: ...g the tank down provided that the temperature of the heat source exceeds the tank temperature by at least the value of the preset Difference 9 plus 3 C T boiler T tank T difference 3 The pump cannot b...

Page 9: ...ower Controller emits a buzzing sound Loose coils in the interference filter does not impact the correct operation of the device Controller knob operates erratically Pulse generator damage send the de...

Page 10: ...voltage may result in increased energy losses in the pumps and in the fan and contribute to malfunction of the whole system 20 KIT CONTENTS a controller with 2 temperature sensors b sensor hose clips...

Page 11: ...the device would not meet your requirements any more you are kindly requested to have it brought in to an electronic waste management facility Electronic waste is collected free of charge by local dis...

Page 12: ...ly by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or making any repairs by unautho...

Reviews: