EUROSTER 11WB User Manual Download Page 10

EUROSTER 11WB 

 USER MANUAL 

 

10

 

 

tank temperature sensor: 5 m 
boiler temperature sensor: 1.5 m 

 

Standards, approvals, certificates 

conformity to EMC, LVD and RoHS

 

Warranty period 

2 years

 

Dimensions (width / height / depth) mm 

150 / 90 / 52

 

It is recommended to use fans equipped with a reactive power compensation circuit.  
Feeding  the  controller  (also  in  the  emergency  mode)  with  a  non-sinusoidal  voltage 
may result in increased energy losses in the pumps and in the fan, and contribute to 
malfunction of the whole system.

 

20.

 

KIT CONTENTS 

a)

 

controller with 2 temperature sensors 

b)

 

sensor hose clips 

c)

 

screw anchors 

d)

 

manual 

e)

 

mounting template 

21.

 

CONNECTION DIAGRAM 

The following diagram is simplified and does not cover all the elements necessary for the 
correct operation of the system. 

 

1.

 

EUROSTER 11WB 

controller 

2.

 

DHW tank temperature sensor 

3.

 

DHW tank 

4.

 

DHW tank filling pump 

5.

 

CH boiler 

6.

 

Blower 

7.

 

Protection  

8.

 

Temperature sensor 

9.

 

CH pump 

10.

 

Heat consumer 

 radiator 

 

Summary of Contents for 11WB

Page 1: ...he operation of the CH and DHW circulation pumps EUROSTER 11WB controller is equipped with an Anti Stop function that prevents seizing of an idle pump rotor It automatically turns the pumps on for 30...

Page 2: ...point specially designed for that purpose or on an unshielded outlet pipe of the CH boiler as close to the boiler as possible fix the DHW sensor on the tank point specially designed for that purpose...

Page 3: ...t while the temperature is manually adjusted 4 Alarm icon blinks in case of alarm 5 Furnace status display see the description below 6 Blower icon lit at the time of blower operation 7 DHW pump icon l...

Page 4: ...g 1 restores factory settings bl Backlight will be displayed and once the knob is released 0 will appear Use the knob to select the required number 0 or 1 and confirm Selecting 0 results in automatic...

Page 5: ...sing between the end of the blow through cycle and the start of a new cycle It should be set so that to prevent the boiler temperature rise but on the other hand to avoid explosive combustion of the g...

Page 6: ...ump calculated by the controller 0 or 1 Press the knob to activate testing of the output Press the knob again or leave it inactive for 10 seconds to resume automatic operation 18 CH pump operation tes...

Page 7: ...tically resume the normal operation mode i e the pumps will not be turned off 11 FUELING Turn the blower off for the time the furnace is loaded with new fuel For this purpose turn the knob all the way...

Page 8: ...g the tank down provided that the temperature of the heat source exceeds the tank temperature by at least the value of the preset Difference 9 plus 3 C T boiler T tank T difference 3 The pump cannot b...

Page 9: ...ower Controller emits a buzzing sound Loose coils in the interference filter does not impact the correct operation of the device Controller knob operates erratically Pulse generator damage send the de...

Page 10: ...voltage may result in increased energy losses in the pumps and in the fan and contribute to malfunction of the whole system 20 KIT CONTENTS a controller with 2 temperature sensors b sensor hose clips...

Page 11: ...the device would not meet your requirements any more you are kindly requested to have it brought in to an electronic waste management facility Electronic waste is collected free of charge by local dis...

Page 12: ...ly by the manufacturer or by other party clearly authorized by the manufacturer 5 Warranty becomes invalidated in case of any mechanical damage incorrect operation and or making any repairs by unautho...

Reviews: