“Autoadaptations precision”
-
defines how many map points (from 16 points nearest to the
current map point) must be collected to make single correction to multiplier. As higher this
value would be as more accurate the collected maps line until autoadaptation will make
single multiplier correction.
Recommended value is between 12 and 16 points depending on the maximum range of
petrol injection opening times.
For proper use of autoadaptation it is necessary to have petrol and gas maps collected accurately.
The petrol and gas map buffers should be full in 100% each. The maps lines mustn't have curves or
gaps in their full scope. The round marker located on two lines intersection should have green
colour in full range of engine loads. The effect of proper usage of autoadaptation has been shown on
below screenshot.
25/42