background image

18 

 

 

BULB REPLACEMENT 

Important:

 

 

  The bulb must be replaced by the manufacturer, its service 

agent or similarly qualified persons. 

 

Always  switch  off  the 

electricity supply before carrying out 

any operations on the appliance. When handling bulb, make 

sure it is completely cooldown before any direct contact to 

hands. 

  When handling globes hold with a cloth or gloves to ensure 

perspiration does not come in contact with the globe as this 

can reduce the life of the globe. 

 

Change the LED light  

Note:

 

  Before changing the lights, make sure that the appliance is plugged off. 

 

Protect against danger when changing lights, such as

 wearing gloves. 

  Light replacement should be carried out by qualified service personnel only. 

 

  Switch the unit off and pull out the plug first. 

  Loose the 4 pcs 4X10MM screws at the back of case, and then take out the outer 

glass. 

  Loose the 2 pcs screws on the lamp bracket, and then change the LED light. See 

pic below. 

  Remove the grease filter. 

 

Unscrew the 4pcs screws on the LED light strip bracket by cross screwdriver, 

dismantle the LED light strip and pull out the terminal of the light connecting wire. 

See pic 1. (

Note: It will need to dismantle the front panel first for models cannot 

directly take down the light strip.) 

 

Apply the reverse procedure to install the light strip back.

 

 

 

 

ILCOS D code for this lamp is:

 DSL-7-S-650

 

– 

Max wattage: 7 W 

 

– 

Voltage range: DC 12V 

 

 

 

Summary of Contents for INLEM3

Page 1: ...User Manual Off Board Undermount Rangehood INLU92BG HOOD INLEM3 INLRCM3 MOTOR ...

Page 2: ...TRUCTIONS This manual explains the proper installation and use of your Rangehood please read it carefully before using even if you are familiar with the product The manual should be keptin a safe place for future reference These instructions shall also be available in an alternative format e g on a website or on request from the user in a spec sheet format ...

Page 3: ...k must be carried out by a competent person or qualified electrician Please dispose of the packing material carefully Children are vulnerable to it Pay attention to the sharp edges inside the Rangehood especially during installation and cleaning When the Rangehood is located above a gas appliance the minimum distance between the supporting surface for the cooking vessels on the hob and the lowest ...

Page 4: ...k if cleaning is not carried out in accordance with the instructions Regulations concerning the discharge of air have to be fulfilled Clean your appliance periodically by following the method given in the chapter MAINTENANCE For safety reason please use only the same size of fixing or mounting screw which are recommended in this instruction manual Regarding the details about the method and frequen...

Page 5: ...ng rafters themselves Ensure the fan motor is level and there is no vibration when in use 3 The location of the fan unit shall allow access for maintenance and repair Permanent fixed means of access is required where the fan unit location is beyond the extent of normal steps or ladders 4 After installation make sure that the main body is level to avoid grease collection at one end 5 Please note th...

Page 6: ...rol wire to achieve power on and off and also speed switching 2 The control wire is separated into 3 parts the first two parts are fixed onto the main body and external cabinet while the middle part is extension wire 3 The Rangehood main body and the external cabinet will exhaust the smoke to outdoor after installing the expansion pipe ...

Page 7: ... 1 you should Mount two half parts 2 into the body 6 a pin 3 should be top oriented the axis 4 should be inserted in the holes 5 on body repeat all the operations for the 2nd half part INSTALLATION If you have an outlet to the outside your Rangehood can be connected as below picture by means of an extraction duct enamel aluminium flexible pipe or non flammable material with an interior diameter of...

Page 8: ...the cabinet make sure the hole edge to the cupboard edge at least 35mm distance 4 Unscrew the 4 screws on the outer glass frame panel by screwdriver pull out the light wire take down the outer glass frame panel see Pic 2 Pic 2 5 Install the outlet seal ring and outlet and fix them with 8 pcs 4 14mm screws see pic 3 Pic 3 ...

Page 9: ...angehood and equip the expansion pipe on the outlet then lead it to outdoor See Pic 4 9 Unscrew the 8 pcs ST4 14mm screws and dismantle the outlet mesh cover see pic 5 Note There is no need to unscrew the 4 screws showing on pic 6 Pic 5 Pic 6 10 Install the outlet seal ring and outlet using the 8 pcs ST4 14mm screws in step 9 to fix them See pic7 11 Install case installation bracket and fix with 4...

Page 10: ...he external cabinet outlet to the outside Both end of the motor extension wire should connect with the external cabinet control wire and the control wire of the main body top The plastic base of the control wire should be plugged to the bottom and make the buckle to tight status See pic 12 Pic 12 Pic 11 Note You need to loosen the connecting wire before repair follow the steps as below a Rotate th...

Page 11: ...n work must be carried out by a qualified electrician or competent person Do not connect the ducting system of the hood to any existing ventilation system which is being used for any other appliance such as warmer tube gas tube hot wind tube The angle of the bend of the expansion pipe should not be less than 120º you must direct the pipe horizontally or alternatively the pipe should go up from the...

Page 12: ...o 3 parts the first two parts are fixed onto the main body and external cabinet while the middle part is extension wire 10 The Rangehood main body and the external cabinet will exhaust the smoke to outdoor after installing the expansion pipe 9 Install the wall mounted bracket and fix with 4 pcs M4 screws spring washers and gaskets See Pic 5 Pic 5 Pic 6 10 Equip the expansion pipe and use stainless...

Page 13: ...dy outlet and fix it with cable tie Connect the motor extension wire both end with the external cabinet control wire and main body top control wire The plastic base of the control wire should be plugged to the bottom and make the bucket to tight status See pic 8 Note You need to loosen the connecting wire before repair follow the steps as below c Rotate the lock catch of the connecting wire follow...

Page 14: ...nd straight Do not reduce the size or restrict expansion pipe When using expansion pipe always install the pipe pulled taut to minimize pressure loss Failure to observe these basic instructions will reduce the performance and increase noise levels of the Rangehood Any installation work must be carried out by a qualified electrician or competent person ...

Page 15: ... the motor runs as low mid high low mid the speed runs circularly and the LED display will indicate as 1 2 3 1 2 circularly 3 Press Light button the light is on press this button again the light is off Please note the Lamp is not under control of the on off button 4 When the hood is working if press the Timer button the hood will go into the status of acquiescent working acquiescent time is 9mins ...

Page 16: ...doubt before undertaking any of the above Always disconnect the unit from the power source when opening the unit MAINTENANCE AND CLEANING Caution Before maintenance or cleaning is carried out the Rangehood should be disconnected from the main power supply Ensure that the Rangehood is switched off at the wall socket and the plug removed External surfaces are susceptible to scratches and abrasions s...

Page 17: ... void manufactures warrantee GREASE MESH FILTERS The mesh filters can be cleaned by hand Soak them for about 3 minutes in water with a grease loosening detergent then brush it gently with a soft brush Please do not apply too much pressure avoid to damage it Leave to dry naturally out of direct sun light Filters should be washed separately to crockery and kitchen utensils it is advisable not to use...

Page 18: ...r when changing lights such as wearing gloves Light replacement should be carried out by qualified service personnel only Switch the unit off and pull out the plug first Loose the 4 pcs 4X10MM screws at the back of case and then take out the outer glass Loose the 2 pcs screws on the lamp bracket and then change the LED light See pic below Remove the grease filter Unscrew the 4pcs screws on the LED...

Page 19: ...more information please contact your local or regional authorities NOTE The following shows how to reduce total environmental impact e g energy use of the cooking process 1 Install the Rangehood in a proper place where there is efficient ventilation 2 Clean the Rangehood regularly so as not to block the airway 3 Remember to switch off the Rangehood light after cooking 4 Remember to switch off the ...

Page 20: ...Distributed by Glen Dimplex Australia Pty Ltd 1340 Ferntree Gully Road Scoresby VIC 3179 Tel 1800 444 357 Email customercare hapl com au Website www euromaid com au ...

Reviews: