![Euromag EUROSONIC 2000 HH User Manual Download Page 40](http://html1.mh-extra.com/html/euromag/eurosonic-2000-hh/eurosonic-2000-hh_user-manual_2439223040.webp)
40 | EUROMAG
Command
DIN(CR)
DIE(CR)
DID(CR)
E(CR)
DL(CR)
DS(CR)
DC(CR)
DA(CR)
DT(CR)
M@(CR)****
LCD(CR)
C1(CR)
C0(CR)
R1(CR)
R0(CR)
FOdddd(CR)
Aoa(CR)
BA1(CR)
BA2(CR)
BA3(CR)
BA4(CR)
AI1(CR)
AI2(CR)
AI3(CR)
AI4(CR)
ESN(CR)
W
N
P
&
RING(CR)(LF)
Function
Return NET totalizer
Return Caloric Totalizer Value
Return Identification Number (IDN)
Return Instantaneous Caloric Value
Return signal strength and signal quality
Return the percentage of analogue output A0.
Return the present error code
OCT or RELAY alarm signal
Return the current date and time
Send a key value as if a key is pressed
Return the current display contents
OCT close
OCT open
RELAY close
RELAY open
Force the FO output to output a frequency of dddd Hz
Output current a at the current loop output terminal
Return current value of AI1 (0-20mA)
Return current value of AI2 (0-20mA)
Return current value of AI3 (0-20mA)
Return current value of AI4 (0-20mA)
Return temperature/pressure value of AI1
Return temperature/pressure value of AI2
Return temperature/pressure value of AI3
Return temperature/pressure value of AI4
Return the electronic serial number (ESN) of the flow meter
Prefix of an IDN-addressing-based networking
command. The IDN address is a word, ranging
0-65534.
Prefix of an IDN-addressing-based networking
command. The IDN address here is a single byte value,
ranging 00-255.
Prefix of any command with checksum
Command binder to make a longer command by
combining up to 6 commands
Handshaking Request from a MODEM
Data Format
±dddddddE±d(CR) (LF)
±dddddddE±d(CR) (LF)
ddddd(CR) (LF)
±d.ddddddE±dd(CR) (LF)
UP:dd.d,DN:dd.d,
Q=dd(CR)(LF)
±d.ddddddE±dd(CR) (LF)
4
TR:s, RL:s(CR)(LF)
5
yy-mm-dd hh:mm:ss(CR)(LF)
M@(CR) )(LF)
6
Fdddd(CR)(LF)
A0a(CR)(LF)
7
±d.ddddddE±dd(CR) (LF)
±d.ddddddE±dd(CR) (LF)
±d.ddddddE±dd(CR) (LF)
±d.ddddddE±dd(CR) (LF)
±d.ddddddE±dd(CR) (LF)
±d.ddddddE±dd(CR) (LF)
±d.ddddddE±dd(CR) (LF)
±d.ddddddE±dd(CR) (LF)
dddddddt(CR)(LF)
8
9
9
ATA(CR) (LF)
It comes from the previous page
It continues in the following page
EUROSONIC 2000 HH
Summary of Contents for EUROSONIC 2000 HH
Page 2: ...EUROSONIC 2000 HH...
Page 6: ...6 EUROMAG EUROSONIC 2000 HH...
Page 12: ...12 EUROMAG EUROSONIC 2000 HH...
Page 28: ...28 EUROMAG EUROSONIC 2000 HH...
Page 34: ...34 EUROMAG EUROSONIC 2000 HH...
Page 38: ...38 EUROMAG EUROSONIC 2000 HH...
Page 44: ...44 EUROMAG EUROSONIC 2000 HH...
Page 77: ...EUROMAG 77...
Page 78: ...78 EUROMAG EUROSONIC 2000 HH...
Page 79: ...EUROMAG 79...