00096441.DOCX, Version 1.0
31/44
CAUTION!
Use two appropriate clamps to rig the fixture on the truss.
Follow the instructions mentioned at the bottom of the base.
Make sure that the device is fixed properly! Ensure that
the structure (truss) to which you are attaching the fixtures is secure.
The fixture’s base enables to be mounted in two ways.
The Moving-Head can be placed directly on the stage
floor or rigged in any orientation on a truss without
altering its operation characteristics (see the drawing).
For overhead use (mounting height >100 cm), always
install an appropriate safety bond.
You must only use safety bonds complying with DIN
56927, quick links complying with DIN 56927,
shackles complying with DIN EN 1677-1 and BGV C1
carbines. The safety bonds, quick links, shackles and
the carbines must be sufficiently dimensioned and
used correctly in accordance with the latest industrial
safety regulations (e. g. BGV C1, BGI 810-3).
Please note:
for overhead rigging in public or
industrial areas, a series of safety instructions have to
be followed that this manual can only give in part. The
operator must therefore inform himself on the current safety instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
Install the safety bond by inserting the quick link in the attachment eyelet on the bottom of the base. Pull the
safety bond over the trussing system etc. Insert the end in the quick link and tighten the fixation screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already hold the strain of a crash or which is defective must not be used again.
DANGER OF FIRE!
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!