Replacing the fuse
If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1:
Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2:
Remove the old fuse from the fuseholder.
Step 3:
Install the new fuse in the fuseholder.
Step 4:
Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
230 V AC, 50 Hz ~
Power consumption:
525 W
DMX-control-channels:
14
DMX-512-connection:
3-pin XLR
Flash-rate:
10 Hz
Colour-wheel:
6 dichroic filters, UV- white
Rotating gobo-wheel:
6 gobos and open
Maximum PAN-movement:
540°
Maximum TILT-movement:
280°
Length of base (including handles):
435 mm
Width:
425 mm
Height (head horizontal):
500 mm
Weight (net):
24.5 kg
Maximum ambient temperature T
a
:
45° C
Maximum housing temperature T
B
(steady state):
85° C
Min.distance from flammable surfaces:
0.5 m
Min.distance to lighted object:
1 m
Fuse:
F 5 A, 250 V
Please note: Every information is subject to change without prior notice. 29.09.2009 ©